6.05 Remove the minimum amount of fiber required for fiber
preparation and splicing. Remove less than one loop if
possible.
6.06 Prepare fibers and complete splice as described in Section 3
and 4.
6.07 Carefully lay the splice on top of the holder without securing
the splice into the holder.
6.08 For 250 to 250 m and 900 to 900 m splices:
a. Store the shorter of the two fibers in the tray.
b. Observe how the splice lays in its relaxed state. Rotate the
splice through the smallest possible angle to install it in the
tray.
c. Store the second fiber.
6.09 For 250 to 900 m splices:
a. Store the 900 m fiber first.
b. Grasping the splice by the 900 m fiber, observe how the
splice lays in its relaxed state. Rotate the splice through
the smallest possible angle to install it in the tray.
c. Store the 250 m fiber.