A SERVICE OF

logo

Page 14 of 36
Solenoid (C Model)
WARNING: Always perform the Electrical Lockout/Tagout procedure before removing
any sheet metal panels or attempting to service this equipment. Failure to comply with
this procedure can cause property damage, injury or death.
WARNING: Perform the GAS LOCKOUT/TAGOUT procedure before servicing the unit.
1. Perform the SOLENOID, PILOT SAFETY AND GAS SHUT-OFF VALVE ASSEMBLY
removal procedure.
2. Remove the flex line fitting from the top of the solenoid.
3. Remove the solenoid from the pipe nipple.
4. Remove any residual tape from the pipe nipples and fittings and coat the threads with
new gas-rated (yellow) Teflon tape.
WARNING: All gas joints disturbed during servicing must be checked for leaks.
Do not use an open flame. Use a hazardous gas tester or a soap and water
solution (Bubbles indicate a gas leak). Failure to comply can cause property
damage, injury or death.
5. Reverse the procedure to install the solenoid.
6. Test the oven to verify proper operation.
Figure 13: C Model Solenoid Removal
Pilot Safety Valve (C Model)
WARNING: Always perform the Electrical Lockout/Tagout procedure before removing
any sheet metal panels or attempting to service this equipment. Failure to comply with
this procedure can cause property damage, injury or death.
WARNING: Perform the GAS LOCKOUT/TAGOUT procedure before servicing the unit.
1. Perform the SOLENOID, PILOT SAFETY AND GAS SHUT-OFF VALVE ASSEMBLY
removal procedure.
2. Remove the flex line and flex line fitting from the pilot safety valve.
3. Remove the screw, lock washer and nut securing the pilot safety valve to the gas mount
bracket.