![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/f/d8/fd85d090-87e5-430a-b067-f282dc30c4fb/fd85d090-87e5-430a-b067-f282dc30c4fb-bg70.png)
112
Electrical
Note:
Check the label on the back of the printer for the voltage of your printer.
Environmental
Paper
Note:
❏ Use recycled paper, envelopes, labels, and single-sheet multipart
forms only under normal temperature and humidity conditions, as
follows:
Temperature: 15 to 25 °C (59 to 77 °F)
Humidity: 30 to 60% RH
❏ Do not load paper that has been folded or is damaged, wrinkled, or
curled.
120 V Model 220 to 240 V Model
Input voltage range 99 to 132 V 198 to 264 V
Rated frequency range 50 to 60 Hz
Input frequency range 49.5 to 60.5 Hz
Rated current 0.6 A (maximum 1.4 A
depending on the
character type)
0.3 A (maximum 0.7 A
depending on the
character type)
Power consumption Approx. 23 W (ISO/IEC 10561 letter pattern)
Temperature Humidity
(without condensation)
Operation 5 to 35 °C (41 to 95 °F) 10 to 80% RH
Storage -30 to 60 °C (-22 to 140 °F) 0 to 85% RH