271457-YTG-B-0908
4 Johnson Controls Unitary Products
— = Not applicable.
Go to www.ari.org/aridirectory for the latest additional matches.
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL MODEL
1
COOLING
MODEL W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
1 PH 13 SEER HP WITH MA
YZB01811 MA08B 17 FC/MC18B 600 18.0 13.2 13.00 11.00
YZB02411
MA08B 17 FC/MC24B 800 22.8 16.7 13.00 11.00
MA08B 17 FC/MC30B 800 22.8 16.7 13.00 11.00
YZB03011 MA12B 17 FC/MC36B 1000 29.2 21.3 13.00 11.00
YZB03611 MA12B 17 FC/MC36B 1200 34.4 25.7 13.00 11.00
YZB04211
MA16C 21 FC/MC48C 1400 41.0 31.8 13.00 11.00
MA14D 21 FC/MC48D 1400 41.0 31.8 13.00 11.00
YZB04811
MA16C 21 FC60C 1600 46.0 34.3 13.00 11.00
MA20D 21 FC/MC60D 1600 46.0 34.3 13.00 11.00
MA20D 24 MC61 1600 46.5 34.9 13.00 11.00
YZB06012 MA20D 24 FC/MC62D 1800 54.0 40.0 13.00 11.00
1 PH 13 SEER HP WITH MV - VARIABLE SPEED
YZB01811 MV12B 17 FC/MC18B 600 17.5 13.0 14.00 11.50
YZB02411
MV12B 17 FC/MC24B 800 23.4 17.1 14.00 11.50
MV12B 17 FC/MC30B 800 23.4 17.1 14.00 11.50
YZB03011
MV12B 17 FC/MC36B 1000 29.0 21.2 14.00 12.00
MV16C 21 FC/MC36C 1000 29.0 21.2 14.00 11.00
YZB03611 MV16C 21 FC/MC36C 1200 36.0 26.9 14.00 11.50
YZB04211
MV16C 21 FC/MC48C 1400 42.0 32.6 14.00 11.50
MV20D 24 FC/MC48D 1400 42.0 32.6 14.00 11.50
YZB04811
MV20D 21 FC60C 1600 46.5 34.7 13.25 11.00
MV20D 24 FC/MC60D 1600 47.0 35.0 13.50 11.00
MV20D 24 MC61D 1600 47.5 35.4 13.50 11.00
YZB06012 MV20D 24 FC/MC62D 1800 54.0 40.5 13.50 11.00
1 PH 13 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED
YZB01811 AV24 17 – 600 18.0 13.0 14.00 11.50
YZB02411 AV24 17 – 800 23.4 17.1 14.00 11.50
YZB03011 AV36 17 – 1000 30.0 21.2 14.00 11.50
YZB03611
AV36 17 – 1200 35.8 26.9 14.00 12.00
AV/SV48 24 – 1200 35.8 26.9 14.00 11.50
YZB04211 AV/SV48 24 – 1400 41.5 32.6 14.00 11.50
YZB04811
AV/SV48 24 – 1600 46.5 34.7 13.50 11.00
F*FV060 24 – 1600 46.5 33.6 13.25 11.00
1 PH 13 SEER AHP WITH AHP / SHP / F*FP
YZB01811
AHP18 17 – 600 18.0 13.2 13.00 11.00
F*FP024 18 – 600 17.9 13.2 13.00 11.00
YZB02411
AHP24 17 – 800 22.8 16.7 13.00 11.00
F*FP030 18 – 800 22.8 16.7 13.00 11.00
YZB03011
AHP30 17 – 1000 29.2 21.1 13.00 11.00
AHP36 17 – 1000 29.2 21.1 13.00 11.00
F*FP036 21 – 1000 29.4 21.2 13.00 11.00
YZB03611
AHP36 21 – 1200 34.4 25.8 13.00 11.00
AHP42 21 – 1200 34.4 25.8 13.00 11.00
F*FP036 21 – 1200 35.0 26.2 13.00 11.00
F*FP042 21 – 1200 35.3 26.2 13.00 11.00
YZB04211 AHP/SHP48 24 – 1400 41.0 31.8 13.00 11.00
YZB04811
AHP/SHP48 24 – 1600 46.0 33.0 13.00 11.00
AHP/SHP60 24 – 1600 46.0 33.0 13.25 11.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.