York YZB018 THRU 060 Air Conditioner User Manual


 
271457-YTG-B-0908
Johnson Controls Unitary Products 11
COOLING CAPACITY - YZB04211With Variable Speed Furnaces
VARIABLE SPEED
FURNACE MODEL
COIL
MODEL
1
W
COOLING
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES
2
PV8*C16 FC/MC/PC48C 21 1400 41.0 28.7 13.25 11.00
PV8*C20 FC/MC/PC48C 21 1400 41.0 28.7 13.50 11.00
P(C,V)9*C16 FC/MC/PC48C 21 1400 41.0 28.7 13.50 11.00
P(C,V)9*C20 FC/MC/PC48C 21 1400 41.0 28.7 13.25 11.00
P(C,V)9*D20 FC/MC/PC48D 24 1400 41.0 28.7 13.50 11.00
Y*(8,L)C*C16 FC/MC/PC48C 21 1435 41.5 31.2 13.80 11.60
Y*(8,L)C*C20 FC/MC/PC48C 21 1410 42.0 31.2 13.90 11.70
Y*9C*C16 FC/MC/PC48C 21 1395 41.5 31.2 13.60 11.50
Y*9C*C20 FC/MC/PC48C 21 1430 41.5 31.0 13.50 11.40
Y*9C*D20 FC/MC/PC48D 24 1450 41.5 31.2 13.70 11.60
Y*(8,L)C*B12 HD48 17 1350 40.5 29.4 13.20 11.20
Y*(8,L)C*C16 HD48 21 1435 42.0 30.8 13.40 11.80
Y*(8,L)C*C20 HD48 21 1410 42.0 30.8 13.50 11.90
Y*9C*B12 HD48 17 1150 39.5 27.6 13.30 11.30
Y*9C*C16 HD48 21 1395 40.5 30.0 13.30 11.20
Y*9C*C20 HD48 21 1430 40.5 30.0 13.20 11.20
Y*9C*D20 HD48 24 1450 42.0 30.8 13.30 11.70
Y*(8,L)C*C16 UC48C 21 1435 41.5 31.2 13.80 11.50
Y*(8,L)C*C20 UC48C 21 1410 41.5 31.2 13.90 11.60
Y*9C*C16 UC48C 21 1395 41.0 31.0 13.60 11.40
Y*9C*C20 UC48C 21 1430 41.0 31.0 13.50 11.30
Y*9C*D20 UC48D 24 1450 41.0 31.0 13.70 11.50
G*9V*C16 FC/MC/PC48C 21 1395 41.5 31.2 13.60 11.50
G*9V*C20 FC/MC/PC48C 21 1430 41.5 31.0 13.50 11.40
G*9V*D20 FC/MC/PC48D 24 1450 41.5 31.2 13.70 11.60
G*9V*B12 HD48 17 1150 39.5 27.6 13.30 11.30
G*9V*C16 HD48 21 1395 40.5 30.0 13.30 11.20
G*9V*C20 HD48 21 1430 40.5 30.0 13.20 11.20
G*9V*D20 HD48 24 1450 42.0 30.8 13.30 11.70
G*9V*C16 UC48C 21 1395 41.0 31.0 13.60 11.40
G*9V*C20 UC48C 21 1430 41.0 31.0 13.50 11.30
G*9V*D20 UC48D 24 1450 41.0 31.0 13.70 11.50
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.