York W)036 THRU 060 Heat Pump User Manual


 
246819-BTG-H-0208
Unitary Products Group 9
COOLING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils
UNIT MODEL
FURNACE**
COIL
MODEL
COOLING
CFM RANGE
(MIN.-MAX.)
W
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.
EABD-F018S
450
750
14,17 FC/MC/PC/UC18 600 18.0 12.4 13.00 11.00
14 HC18 600 17.8 12.1 13.00 11.00
EABD-F024S
600
1000
14,17 FC/MC/PC/UC24 800 23.2 16.7 13.00 11.00
14,17 FC/MC/PC/UC30 800 23.2 16.7 13.00 11.00
14 HC30 760 23.4 16.6 13.00 11.00
HD24 800 23.2 16.7 13.00 11.00
EABD-F030S
800
1200
17,21 FC/MC/PC35 1000 28.4 20.3 13.00 11.00
17,21 FC/MC/PC/UC42 1000 28.4 20.3 13.00 11.00
17 HC36 950 28.0 19.6 13.00 11.00
HD36 1000 28.6 20.3 13.00 11.00
EABD-(T,W)030S
800
1200
17,21 FC/MC/PC35 1000 28.0 20.0 13.00 11.00
17,21 FC/MC/PC/UC42 1000 28.0 20.0 13.00 11.00
17 HC36 950 27.6 19.3 13.00 11.00
HD36 1000 28.2 20.0 13.00 11.00
EABD-F036S
1000
1400
17,21 FC/MC/PC35 1200 34.6 25.3 13.00 11.00
17,21 FC/MC/PC/UC42 1200 34.6 25.3 13.00 11.00
21,24 FC/MC/PC/UC48 1200 35.0 25.6 13.00 11.00
21 HC42 1140 34.4 24.5 13.00 11.00
HD36 1200 34.4 25.2 13.00 11.00
EABD-(T,W)036S
1000
1400
17,21 FC/MC/PC35 1200 34.0 24.8 13.00 11.00
17,21 FC/MC/PC/UC42 1200 34.0 24.8 13.00 11.00
21,24 FC/MC/PC/UC48 1200 34.4 25.1 13.00 11.00
21 HC42 1140 33.8 24.0 13.00 11.00
HD36 1200 33.8 24.7 13.00 11.00
EABD-F042S
1200
1000
21,24 FC/MC/PC/UC48 1400 41.0 30.8 13.00 11.00
HD48 1400 40.5 30.3 13.00 11.00
EABD-(T,W)042S
1200
1600
21,24 FC/MC/PC/UC48 1400 40.0 30.0 13.00 11.00
HD48 1400 39.5 29.5 13.00 11.00
EABD-F048S
1400
1800
21,24 FC/MC/PC/UC60 1600 45.0 35.4 13.00 11.00
24 MC61 1600 46.0 35.5 13.00 11.00
24 HC60 1520 45.5 34.3 13.00 11.00
HD60 1600 45.0 34.7 13.00 11.00
EABD-(T,W)048S
1400
1800
21,24 FC/MC/PC/UC60 1600 44.0 34.6 13.00 11.00
24 MC61 1600 45.0 34.7 13.00 11.00
24 HC60 1520 44.5 33.5 13.00 11.00
HD60 1600 44.0 33.9 13.00 11.00
EABD-F060S
1600
2000
21,24 FC/MC/PC/UC60 1800 55.0 40.7 13.00 11.00
24 MC61 1800 55.5 41.0 13.00 11.00
24 HC60 1710 54.5 39.7 13.00 11.00
HD60 1800 54.0 39.9 13.00 11.00
EABD-(T,W)060S
1600
2000
21,24 FC/MC/PC/UC60 1800 54.5 40.3 13.00 11.00
24 MC61 1800 55.0 40.6 13.00 11.00
24 HC60 1710 54.0 39.3 13.00 11.00
HD60 1800 53.5 39.5 13.00 11.00
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
** Refer to Quick Selection Chart for specific furnace match-up.