York W)036 THRU 060 Heat Pump User Manual


 
246819-BTG-H-0208
Unitary Products Group 31
Multipliers for determining the performance with other indoor sections.
* = Single-phase outdoor units only.
* = Single-phase outdoor units only.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO EABD-F060S, EABD-(T,W)060S**
EVAPORATOR COIL MODEL NO FC/MC/PC/UC60
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
1600 1800 2000
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 72.1 4.4 4.3 72.8 4.1 4.5 73.6 3.9 4.6
70 71.0 4.9 3.8 71.8 4.7 3.9 72.5 4.4 4.1
80 69.9 5.5 3.4 70.7 5.3 3.5 71.4 5.0 3.7
47
60 60.0 4.1 3.8 60.7 3.9 3.9 61.4 3.7 4.1
70 57.2 4.6 3.2 58.0 4.2 3.5 60.3 4.2 3.6
80 58.5 5.2 3.0 57.8 5.0 3.0 59.1 4.7 3.2
40
60 48.4 3.9 3.2 50.7 3.8 3.3 53.1 3.7 3.5
70 48.8 4.4 2.9 51.0 4.3 3.0 53.2 4.2 3.2
80 49.3 5.0 2.6 51.3 4.8 2.8 53.3 4.6 2.9
30
60 44.4 3.7 3.1 42.0 3.5 2.9 39.7 3.4 2.8
70 43.9 4.2 2.7 43.3 4.1 2.7 42.8 3.9 2.7
80 43.4 4.8 2.4 44.6 4.6 2.5 45.8 4.5 2.6
17
60 37.4 3.5 2.7 36.2 3.5 2.6 35.0 3.4 2.5
70 34.9 3.9 2.3 35.0 3.8 2.3 36.2 3.8 2.3
80 32.4 4.3 1.9 34.9 4.3 2.1 37.4 4.2 2.2
10
60 29.0 3.6 2.0 30.1 3.4 2.2 31.2 3.3 2.3
70 30.6 4.0 2.0 31.1 3.9 2.0 31.7 3.9 2.0
80 32.1 4.4 1.9 32.2 4.4 1.9 32.2 4.4 1.8
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
** For three-phase, decrease T.C. by 1.0 and S.C. by 0.7.
Air Handler Coil
T.C. S.C. KW
MA20D FC/MC60D 1.00 1.00 1.00
MA20D MC61D 1.00 1.00 1.00
AHP/SHP60 1.00 1.02 1.02
F*FV060* 0.99 0.99 0.98
MV20D* FC/MC60D 0.99 0.99 0.98
MV20D* MC61D 0.99 0.98 0.97
AV/SV60* 0.99 0.99 0.98
HC60 0.99 1.01 1.00
HD60 1.00 1.00 1.00
MC61 1.00 1.00 1.00
Variable Speed
Furnace *
Coil
T.C. S.C. KW
FL9(C,V)D20 FC/MC/PC60D 0.97 0.99 0.95
(F,L)L8VC20 FC/PC60C 0.99 0.99 0.99
FL9(C,V)C20 FC/PC60C 0.98 1.00 1.00
FL9(C,V)D20 HC60 0.97 0.99 0.96
(F,L)L8VC20 HD60 0.97 0.99 0.99
FL9(C,V)D20 HD60 0.97 0.99 0.96
FL9(C,V)D20 MC61D 0.97 0.99 0.95