York R-410A Air Conditioner User Manual


 
528195-YTG-B-0810
Johnson Controls Unitary Products 21
115°F 125°F
2500
77 111.3 11.5 44.2 37.9 28.1 - - - 102.2 12.7 45.2 30.9 25.1 - - -
72 101.2 11.4 67.7 56.3 44.9 33.6 - - 92.5 12.6 64.0 52.7 41.5 30.2 - -
67 91.1 11.3 91.1 74.8 61.8 50.4 39.1 - 82.8 12.5 82.8 71.8 57.9 46.6 35.3 -
62 85.0 11.2 85.0 85.0 67.1 55.8 44.4 33.0 77.0 12.4 77.0 77.0 58.9 47.6 36.3 25.1
3000
77 115.3 11.6 62.3 45.5 31.7 - - - 105.5 12.8 65.3 42.7 28.6 - - -
72 104.9 11.5 78.4 64.5 50.7 36.8 - - 95.5 12.7 75.4 61.3 47.2 33.1 - -
67 94.4 11.4 94.4 83.5 69.7 55.8 42.0 - 85.5 12.6 85.5 80.0 65.9 51.8 37.7 -
62 88.1 11.3 88.1 88.1 75.7 61.9 48.0 34.2 79.5 12.5 79.5 79.5 67.2 53.1 39.0 24.9
57 87.1 11.4 87.1 87.1 76.5 62.7 48.8 35.0 78.6 12.5 78.6 78.6 68.4 54.3 40.2 26.1
3500
77 119.4 11.7 80.3 53.2 35.3 - - - 108.8 12.9 85.4 54.4 32.1 - - -
72 108.5 11.6 89.0 72.7 56.4 40.1 - - 98.5 12.8 86.8 69.9 53.0 36.1 - -
67 97.7 11.5 97.7 92.3 77.6 61.3 45.0 - 88.1 12.7 88.1 88.1 73.9 57.0 40.1 -
62 91.2 11.4 91.2 91.2 84.3 68.0 51.6 35.3 82.0 12.6 82.0 82.0 75.5 58.6 41.7 24.8
57 90.1 11.5 90.1 90.1 85.2 68.9 52.6 36.3 81.1 12.7 81.1 81.1 76.8 59.9 43.0 26.1
4000
77 123.4 11.8 98.4 60.8 38.9 - - - 112.1 13.0 105.5 66.1 35.6 - - -
72 112.2 11.7 99.7 80.9 62.2 43.4 - - 101.5 12.9 98.2 78.5 58.8 39.0 - -
67 101.0 11.6 101.0 101.0 85.5 66.7 47.9 - 90.8 12.9 90.8 90.8 81.9 62.2 42.5 -
62 94.2 11.5 94.2 94.2 92.8 74.1 55.3 36.5 84.4 12.7 84.4 84.4 83.7 64.0 44.3 24.6
57 93.2 11.5 93.2 93.2 93.8 75.1 56.3 37.5 83.6 12.8 83.6 83.6 83.6 65.5 45.8 26.1
4500
72 113.4 11.7 105.0 85.4 65.8 46.3 - - 102.1 12.9 102.1 82.4 62.1 41.7 - -
67 102.1 11.6 102.1 102.1 90.5 70.9 51.4 - 91.4 12.8 91.4 91.4 86.5 66.2 45.9 -
62 95.3 11.5 95.3 95.3 94.6 75.0 55.4 35.8 84.9 12.7 84.9 84.9 84.6 64.3 44.0 23.7
57 94.2 11.5 94.2 94.2 94.5 74.9 55.4 35.8 84.0 12.7 84.0 84.0 84.0 64.6 44.3 23.9
5000
72 114.6 11.6 110.3 89.9 69.5 49.1 - - 102.7 12.8 102.7 86.3 65.4 44.4 - -
67 103.2 11.5 103.2 103.2 95.6 75.2 54.8 - 91.9 12.7 91.9 91.9 91.1 70.2 49.3 -
62 96.3 11.4 96.3 96.3 96.3 75.9 55.5 35.1 85.4 12.6 85.4 85.4 85.4 64.5 43.6 22.7
57 95.2 11.5 95.2 95.2 95.2 74.8 54.4 34.0 84.5 12.7 84.5 84.5 84.5 63.6 42.7 21.8
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
XP120 (10 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F) Return Dry Bulb (°F)
90 85 80 75 70 65 90 85 80 75 70 65