York R-410A Air Conditioner User Manual


 
528195-YTG-B-0810
Johnson Controls Unitary Products 19
115°F 125°F
2125
77 98.9 10.0 41.2 36.0 26.8 - - - 90.2 11.1 44.1 31.8 25.3 - - -
72 89.2 9.9 60.4 50.3 40.1 30.0 - - 81.3 11.0 58.2 48.0 37.8 27.6 - -
67 79.6 9.8 79.6 64.5 53.4 43.3 33.2 - 72.4 10.9 72.4 62.0 50.4 40.2 30.0 -
62 73.4 9.7 73.4 73.4 65.6 55.4 45.3 35.2 66.2 10.8 66.2 66.2 66.2 52.3 42.2 32.0
2550
77 102.3 10.0 55.9 42.2 30.3 - - - 93.3 11.1 59.4 40.8 28.8 - - -
72 92.4 9.9 69.1 57.3 45.4 33.5 - - 84.1 11.0 67.2 55.1 43.1 31.1 - -
67 82.4 9.8 82.4 72.3 60.5 48.6 36.7 - 74.9 10.9 74.9 69.4 57.4 45.4 33.4 -
62 76.0 9.8 76.0 76.0 74.1 62.3 50.4 38.5 68.5 10.8 68.5 68.5 68.5 59.2 47.2 35.2
57 79.1 9.8 79.1 79.1 67.5 55.6 43.7 31.8 73.1 10.8 73.1 73.1 61.6 49.6 37.6 25.5
2975
77 105.8 10.1 70.7 48.4 33.8 - - - 96.4 11.2 74.8 49.9 32.3 - - -
72 95.5 10.0 77.9 64.3 50.6 37.0 - - 86.9 11.0 76.1 62.2 48.4 34.6 - -
67 85.1 9.9 85.1 80.1 67.5 53.8 40.2 - 77.3 10.9 77.3 76.9 64.5 50.6 36.8 -
62 78.5 9.8 78.5 78.5 82.7 69.1 55.5 41.8 70.7 10.8 70.7 70.7 70.7 66.1 52.3 38.5
57 81.8 9.8 81.8 81.8 75.3 61.6 48.0 34.4 75.6 10.9 75.6 75.6 69.2 55.3 41.5 27.7
3400
77 109.2 10.1 85.4 54.6 37.3 - - - 99.5 11.2 90.2 58.9 35.9 - - -
72 98.6 10.0 86.6 71.3 55.9 40.5 - - 89.7 11.1 85.0 69.4 53.7 38.0 - -
67 87.9 9.9 87.9 87.9 74.5 59.1 43.7 - 79.8 10.9 79.8 79.8 71.5 55.8 40.2 -
62 81.1 9.8 81.1 81.1 91.3 75.9 60.6 45.2 73.0 10.9 73.0 73.0 73.0 73.0 57.4 41.7
57 84.4 9.9 84.4 84.4 83.1 67.7 52.3 37.0 78.0 10.9 78.0 78.0 76.8 61.1 45.5 29.8
3825
72 100.3 10.0 93.9 76.9 60.0 43.0 - - 91.0 11.1 91.0 75.1 57.8 40.5 - -
67 89.4 9.9 89.4 89.4 79.9 63.0 46.0 - 81.0 11.0 81.0 81.0 76.9 59.6 42.3 -
62 82.5 9.9 82.5 82.5 87.6 70.7 53.7 36.8 74.0 10.9 74.0 74.0 74.0 64.6 47.3 30.0
57 85.9 9.9 85.9 85.9 85.2 68.3 51.3 34.4 79.1 10.9 79.1 79.1 78.5 61.2 43.9 26.6
4250
72 101.9 10.1 101.1 82.6 64.1 45.6 - - 92.3 11.1 92.3 80.8 61.8 42.9 - -
67 90.9 10.0 90.9 90.9 85.4 66.8 48.3 - 82.1 11.0 82.1 82.1 82.1 63.4 44.4 -
62 83.9 9.9 83.9 83.9 83.9 65.4 46.8 28.3 75.1 10.9 75.1 75.1 75.1 56.2 37.2 18.3
57 87.3 9.9 87.3 87.3 87.3 68.8 50.3 31.8 80.3 11.0 80.3 80.3 80.3 61.3 42.4 23.4
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
XP102 (8.5 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F) Return Dry Bulb (°F)
90 85 80 75 70 65 90 85 80 75 70 65