York H*RD018 THRU 060 Air Conditioner User Manual


 
254892-YTG-C-0606
Unitary Products Group 3
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase
Outdoor Unit H2RD018S06 H2RD024S06 H2RD030S06 H2RD036S06 H2RD042S06 H2RD048S06 H2RD060S06
Required TXV 1TVM2A1 1TVM2(A,B)1 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1
Factory R-22 Charge, lbs-oz 4 - 9 6 - 3 5 - 13 6 - 0 8 - 13 8 - 6 10 - 2
Indoor Coil
1,2
TXV KIT
3
- Additional Charge, Oz
FC/MC/PC/UC/UC18A2A 0 ––––––
FC/MC/PC/UC18B2A 0 ––––––
FC/MC/PC/UC24A2A 0 0 –––––
FC/MC/PC/UC24B2A 0 0 –––––
FC/MC/PC/UC30A2A –0 0 ––––
FC/MC/PC/UC30B2A –0 0 ––––
FC/MC/PC/UC36A2A ––0 0 –––
FC/MC/PC/UC36B2A ––0 0 –––
FC/MC/PC/UC36C2A ––0 0 –––
FC/MC/PC/UC42B2C ––––0 ––
FC/MC/PC/UC42C2C ––––0 ––
FC/MC/PC/UC48C2C ––––0 0
FC/MC/PC/UC48D2C ––––0 0
FC/PC/UC/UC60C2C ––––––0
FC/MC/PC/UC60D2C ––––––0
MC61D2C ––––––0
HC18A2A 0 ––––––
HC30A2A –0 0 ––––
HC36B2A – – 0 0 – – –
HC42C2C ––––0 0
HC60C2C –––––0 0
HD24A2A 0 0 –––––
HD36B2A – – 0 0 – – –
HD48C2C ––––0 0
HD60D2C –––––0 0
AHP18B2A 0 ––––––
AHP24B2A 0 0 –––––
AHP30B2A –0 0 ––––
AHP36C2A – – 0 0 – – –
AHP42C2C ––––0 ––
AHP/SHP48D2C ––––0 0
AHP/SHP60D2C –––0 0 0 0
AV24B2A 0 0 – – – –
AV36C2A – 0 0 – – –
AV/SV48D2C ––––0 0
AV/SV60D2C ––––0 0 0
FC/MC/PC/UC18A3X 0 2B + 1 –––––
FC/MC/PC/UC18B3X 0 2B + 1 –––––
FC/MC/PC/UC24A3X 0 2A + 0 –––––
FC/MC/PC/UC24B3X 0 2A + 0 –––––
FC/MC/PC/UC30A3X 2A + 0 0 ––––
FC/MC/PC/UC30B3X 2A + 0 0 ––––
FC/MC/PC/UC36A3X ––0 0 –––
FC/MC/PC/UC36B3X ––0 0 –––
FC/MC/PC/UC36C3X ––0 0 –––
FC/MC/PC/UC42B3X ––––0 ––
FC/MC/PC/UC42X3X ––––0 ––
FC/MC/PC/UC48C3X ––––0 0
FC/MC/PC/UC48D3X ––––0 0
FC/PC/UC/UC60C3X ––––––0
FC/MC/PC/UC60D3X ––––––0
MC61D3X ––––––0
For Notes See Page 5.