York H*RD018 THRU 060 Air Conditioner User Manual


 
254892-YTG-C-0606
10 Unitary Products Group
— = Not applicable.
1 PH 13 SEER AC WITH AV / SV - VARIABLE SPEED
H2RD018S06 AV24 2,5,8,10,15 17 – 600 18.0 11.7 14.00 11.50
H2RD024S06 AV24 2,5,8,10,15 17 – 800 23.2 16.5 14.00 11.50
H2RD030S06 AV36 5,8,10,15,18 21 – 1000 30.0 21.2 14.00 11.50
H2RD036S06
AV36 5,8,10,15,18 21 1200 35.2 25.0 14.00 11.50
AV/SV48 5,8,10,15,18,20,25 24 1200 35.8 25.0 13.75 11.00
H2RD042S06 AV/SV48 5,8,10,15,18,20,25 24 1400 40.5 29.1 14.00 11.50
H2RD048S06 AV/SV48 5,8,10,15,18,20,25 24 1600 47.0 34.7 13.50 11.00
H2RD060S06 AV/SV60 5,8,10,15,18,20,25 24 1800 55.0 39.1 13.15 11.00
1 & 3 PH 13 SEER AC WITH AHP / F*FP / F*FV
H2RD018S06
AHP18 2,5,8 17 650 17.7 12.3 13.00 11.00
AHP24 2,5,8,10 17 – 655 17.9 12.5 13.50 11.00
F*FP024 5,8,10 17 – 650 17.5 12.2 13.00 11.00
H2RD024S06
AHP24 2,5,8,10 17 – 830 23.0 16.8 13.00 11.00
AHP30 5,8,10 17 795 23.6 17.0 13.00 11.00
F*FP024 5,8,10 17 – 800 23.0 16.8 13.00 11.00
F*FP030 5,8,10,15 17 800 23.0 16.8 13.00 11.00
H2RD030S06
AHP30 5,8,10 17 1015 30.0 21.9 13.00 11.00
AHP36 5,8,10,15,18 17 1040 30.0 22.6 13.50 11.00
F*FP036 5,8,10,15,19 21 1000 29.6 21.3 13.00 11.00
H1RD030S(25,46)
AHP30 5,8,10 17 1015 29.7 21.7 13.00 11.00
AHP36 5,8,10,15,18 17 1040 29.7 22.4 13.50 11.00
F4FP036 5,8,10,15,19 21 1000 29.3 21.1 13.00 11.00
H2RD036S06
AHP36 5,8,10,15,18 17 1235 35.0 27.2 13.50 11.00
AHP42 5,8,10,15,18 21 1255 35.0 27.5 13.50 11.00
AHP/SHP60 5,8,10,15,20,25 24 1200 36.0 26.7 14.00 11.50
F*FP040 5,8,10,15 21 1200 34.8 25.4 13.00 11.00
H1RD036S(25,46)
AHP36 5,8,10,15,18 17 1235 34.7 27.0 13.50 11.00
AHP42 5,8,10,15,18 21 1255 34.7 27.3 13.50 11.00
AHP/SHP60 5,8,10,15,20,25 24 1200 35.7 26.5 14.00 11.50
F*FP040 5,8,10,15 24 1200 34.5 25.2 13.00 11.00
H2RD042S06
AHP42 5,8,10,15,18 21 1485 41.0 31.0 13.00 11.00
AHP/SHP48 5,8,10,15,20 24 1400 42.0 30.7 13.50 11.00
AHP/SHP60 5,8,10,15,20,25 24 1400 40.5 33.2 14.00 11.50
F*FP048 5,8,10,15 24 1400 41.0 31.0 13.00 11.00
H1RD042S(25,46)
AHP42 5,8,10,15,18 21 1485 40.0 30.3 13.00 11.00
AHP/SHP48 5,8,10,15,20 24 1400 41.0 30.0 13.50 11.00
AHP/SHP60 5,8,10,15,20,25 24 1400 39.5 32.5 14.00 11.50
F4FP048 5,8,10,15 24 1400 40.0 30.3 13.00 11.00
H2RD048S06
F*FV060 5,8,10,15,20,25 24 1600 47.5 36.9 13.50 11.00
AHP/SHP48 5,8,10,15,20 24 1675 47.0 36.8 13.00 11.00
AHP/SHP60 5,8,10,15,20,25 24 1600 47.0 36.2 13.75 11.00
H1RD048S(25,46)
AHP/SHP48 5,8,10,15,20 24 1675 46.0 36.1 13.00 11.00
AHP/SHP60 5,8,10,15,20,25 24 1600 46.0 35.5 13.75 11.00
H2RD060S06
F*FV060 5,8,10,15,20,25 24 1850 55.0 40.3 13.20 11.00
AHP/SHP60 5,8,10,15,20,25 24 1850 55.0 40.3 13.00 11.00
H1RD060S(25,46) AHP/SHP60 5,8,10,15,20,25 24 1850 54.0 39.6 13.00 11.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL MODEL
1
COOLING
MODEL
ELECTRIC
HEAT KW
2
W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.