York E*BD-F018 THRU 060 Heat Pump User Manual


 
246819-BTG-H-0208
Unitary Products Group 5
All dimensions are in inches. They are subject to change with-
out notice. Certified dimensions will be provided upon request.
Physical and Electrical Data - 3 Phase
MODEL
EABD-
T030S
EABD-
T036S
EABD-
T042S
EABD-
T048S
EABD-
T060S
EABD-
W030S
EABD-
W036S
EABD-
W042S
EABD-
W048S
EABD-
W060S
Unit Supply Voltage 208-230V, 3φ, 60Hz 460V, 3φ, 60Hz
Normal Voltage Range
1
187 to 252 432 to 532
Minimum Circuit Ampacity 12.1 14.3 14.4 20.2 23.1 5.6 6.9 7.2 9.5 11.2
Max. Overcurrent Device Amps
2
20 20 20 35 40 15 15 15 15 15
Min. Overcurrent Device Amps
3
15 15 15 25 25 15 15 15 15 15
Compressor Type Recip Recip Recip Scroll Scroll Recip Recip Recip Scroll Scroll
Compressor Amps
Rated Load 8.5 10.2 10.4 15.0 16 3.9 4.9 6.1 6.1 8
Locked Rotor 62 72 71 95 123 30 45 45 45 70
Crankcase Heater Yes Yes Yes No No Yes Yes Yes No No
Fan Motor Amps Rated Load 1.5 1.5 1.5 1.5 1.5 0.7 0.7 0.7 0.7 0.7
Fan Diameter Inches 22 22 22 24 24 22 22 22 24 24
Fan Motor
Rated HP 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Nominal RPM 850 850 850 850 850 850 850 850 850 850
Nominal CFM 3450 3500 3500 3400 3500 3450 3500 3500 3400 3500
Coil
Face Area Sq. Ft. 20.96 23.58 23.58 24.00 27.00 20.96 23.58 23.58 24.00 27.00
Rows Deep 1112211122
Fin / Inches 22 22 22 18 18 22 22 22 18 18
Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Vapor Line Set OD (Field Installed) 7/8 7/8 7/8 7/8 1-1/8 7/8 7/8 7/8 7/8 1-1/8
Unit Charge (Lbs. - Oz.)
4
8 - 7 8 - 7 8 - 7 12 - 8 16 - 7 8 - 7 8 - 7 8 - 7 12 - 8 16 - 7
Charge Per Foot, Oz. 0.70 0.70 0.70 0.70 0.76 0.70 0.70 0.70 0.70 0.78
Operating Weight Lbs. 196 208 208 250 294 196 208 208 250 294
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than
15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. If line exceeds 25
feet, you may refer to publications software 036-68001-001 for proper line sizing.
C
B
A
DIMENSIONS
Unit
Model
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
A
1
1. Including Fan Guard.
* Adapter fitting required for 1-1/8” line set.
B C Liquid Vapor
030 35 37 27
3/8”
7/8”
036 39 37 27
042 39 37 27
048 34 43 32
060 38 43 32 7/8”*