York E*BD-F018 THRU 060 Heat Pump User Manual


 
246819-BTG-H-0208
Unitary Products Group 3
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase
Outdoor Unit EABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060S
Required TXV 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1
Factory Charge, lbs-oz 7 - 1 6 - 9 8 - 9 8 - 7 8 - 7 12 - 8 16 - 7
Indoor Coil
1,2
Additional Charge, Oz
FC/MC/PC/UC18A2A 0––––––
FC/MC/PC/UC18B2A 0––––––
FC/MC/PC/UC24A2A –0–––––
FC/MC/PC/UC24B2A –0–––––
FC/MC/PC/UC30A2A –0–––––
FC/MC/PC/UC30B2A –0–––––
FC/MC/PC35B2A ––09–––
FC/MC/PC35C2C ––09–––
FC/MC/PC/UC42B2C ––09–––
FC/MC/PC/UC42C2C ––09–––
FC/MC/PC/UC48C2C 9 14
FC/MC/PC/UC48D2C 9 14
FC/PC/UC60C2C –––––77
FC/MC/PC/UC60D2C –––––77
MC61D2C –––––77
HC18A2A 0––––––
HC30A2A –0–––––
HC36B2A ––0––––
HC42C2C –––9–––
HC60C2C –––––77
HD24A2A –0–––––
HD36B2A ––09–––
HD48C2C 14
HD60D2C –––––77
AHP18B2A 0––––––
AHP24B2A –0–––––
AHP30B2A ––0––––
AHP36C2A –––9–––
AHP42C2C –––9–––
AHP/SHP48D2C 14 7
AHP/SHP60D2C –––––77
AV24B2A 00–––––
AV36C2A ––09–––
AV/SV48D2C 14 7
AV/SV60D2C ––––––7
FC/MC/PC/UC18A3X 0––––––
FC/MC/PC/UC18B3X 0––––––
FC/MC/PC/UC24A3X –0–––––
FC/MC/PC/UC24B3X –0–––––
FC/MC/PC/UC30A3X –0–––––
FC/MC/PC/UC30B3X –0–––––
FC/MC/PC35B3X ––09–––
FC/MC/PC35X3X ––09–––
FC/MC/PC/UC42B3X ––09–––
FC/MC/PC/UC42X3X ––09–––
FC/MC/PC/UC48C3X 9 14
FC/MC/PC/UC48D3X 9 14
FC/PC/UC60C3X –––––77
FC/MC/PC/UC60D3X –––––77
MC61D3X –––––77
HC18A3X 0––––––
HC30A3X –0–––––
HC36B3X ––0––––
HC42C3X –––9–––
HC60C3X –––––77
For Notes See Page 4.