York BP 036 Heat Pump User Manual


 
255027-YTG-B-0507
Unitary Products Group 23
TABLE 16: SUPPLY AIR BLOWER PERFORMANCE (BP036, 048, 060 & 072 DIRECT DRIVE) -
SIDE FLOW APPLICATION
UNIT
TONNAGE
MOTOR
SPEED
AVAILABLE EXTERNAL STATIC PRESSURE - IWG
1
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
3
2
HI 1582 320 1538 335 1496 349 1458 363 1418 376 1381 390 1338 403 1298 417 1255 430
MED/HI 1488 263 1440 276 1396 290 1354 303 1309 316 1263 329 1214 343 1158 358 1085 374
MED 1339 208 1292 221 1247 234 1201 246 1152 258 1102 272 1036 288 967 303 924 313
MED/LOW 1233 171 1184 183 1135 195 1082 207 1026 220 957 235 895 248 - - - -
LOW 1081 130 997 134 935 145 863 158 - - - - - - - - - -
4
2
HI 2056 636 2017 696 1978 714 1942 734 1906 749 1864 764 1815 769 1728 743 1582 685
MED/HI 1866 539 1832 557 1795 571 1754 585 1722 602 1679 619 1636 638 1582 653 1508 639
MED 1680 408 1641 426 1594 438 1558 455 1517 472 1469 490 1415 505 1370 521 1337 536
MED/LOW 1582 362 1541 380 1495 391 1465 406 1426 423 1377 440 1326 455 1292 469 1247 485
LOW 1300 223 1258 237 1202 247 - - - - - - - - - - - -
5
2
HI 2256 883 2258 931 2247 950 2223 964 2182 979 2125 971 2044 940 1958 898 1864 854
MED/HI 2145 771 2127 784 2119 808 2089 826 2051 844 2014 859 1965 861 1896 843 1801 806
MED 2020 637 1999 656 1985 675 1947 696 1910 715 1876 730 1832 740 1793 756 1725 748
MED/LOW 1757 413 1713 432 1677 451 1639 468 1597 479 1559 497 1521 513 1472 523 - -
LOW 1570 327 1536 339 1499 356 - - - - - - - - - - - -
6
2
HI 2256 883 2258 931 2247 950 2223 964 2182 979 2125 971 2044 940 1958 898 1864 854
MED/HI 2145 771 2127 784 2119 808 2089 826 2051 844 2014 859 1965 861 1896 843 1801 806
MED 2020 637 1999 656 1985 675 1947 696 1910 715 1876 730 1832 740 1793 756 - -
MED/LOW------------------
LOW------------------
1. Includes allowances for a wet evaporator coil, 1” filters. Refer to STATIC RESISTANCES Table for resistance values.
2. Side Flow application (230 Volts)
TABLE 17: SUPPLY AIR BLOWER PERFORMANCE (BP036, 048, 060 & 072 DIRECT DRIVE) -
BOTTOM FLOW APPLICATION
UNIT
TONNAGE
MOTOR
SPEED
AVAILABLE EXTERNAL STATIC PRESSURE - IWG
1
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
3
2
HI 1527 320 1485 335 1445 349 1408 363 1370 376 1334 390 1292 403 1254 417 1213 430
MED/HI 1437 263 1391 276 1349 290 1308 303 1265 316 1221 329 1174 343 1120 358 1049 374
MED 1293 208 1248 221 1205 234 1161 246 1114 258 1065 272 1002 288 935 303 894 313
MED/LOW 1191 171 1144 183 1097 195 1046 207 992 220 926 235 866 248 - - - -
LOW 1045 130 964 134 904 145 - - - - - - - - - - - -
4
2
HI 1985 636 1947 696 1909 714 1875 734 1840 749 1800 764 1752 769 1668 743 1528 685
MED/HI 1802 539 1768 557 1733 571 1694 585 1662 602 1621 619 1580 638 1528 653 1456 639
MED 1622 408 1585 426 1539 438 1505 455 1465 472 1419 490 1367 505 1324 521 1291 536
MED/LOW 1528 362 1489 380 1444 391 1415 406 1377 423 1330 440 1281 455 1248 469 1205 485
LOW 1256 223 1216 237 1161 247 - - - - - - - - - - - -
5
2
HI 2177 883 2179 931 2169 950 2145 964 2106 979 2051 971 1973 940 1890 898 1800 854
MED/HI 2071 771 2053 784 2045 808 2016 826 1980 844 1944 859 1897 861 1830 843 1739 806
MED 1950 637 1929 656 1916 675 1880 696 1844 715 1811 730 1768 740 1731 756 1665 748
MED/LOW 1697 413 1654 432 1619 451 1583 468 1542 479 1506 497 1469 513 - - - -
LOW 1516 327 1484 339 1448 356 - - - - - - - - - - - -
6
2
HI 2177 883 2179 931 2169 950 2145 964 2106 979 2051 971 1973 940 1890 898 1800 854
MED/HI 2071 771 2053 784 2045 808 2016 826 1980 844 1944 859 1897 861 1830 843 - -
MED 1950 637 1929 656 1916 675 1880 696 1844 715 1811 730 1768 740 - - - -
MED/LOW------------------
LOW------------------
1. Includes allowances for a wet evaporator coil, 1” filters. Refer to STATIC RESISTANCES Table for resistance values.
2. Bottom Flow application (230 Volts)