York BP 036 Heat Pump User Manual


 
255027-YTG-B-0507
Unitary Products Group 15
072
(6)
1800
55
MBH 11.3 20.8 30.3 39.8 49.2 58.7 68.2 77.7
KW 3.4 3.7 4.0 4.2 4.5 4.8 5.0 5.3
70
MBH 10.1 19.6 29.0 38.5 48.0 57.5 66.9 76.4
KW 4.1 4.4 4.6 4.9 5.2 5.4 5.7 6.0
80
MBH 7.9 17.3 26.8 36.3 45.8 55.2 64.7 74.2
KW 4.6 4.8 5.1 5.4 5.6 5.9 6.2 6.4
2400
55
MBH 13.2 22.6 32.1 41.6 51.1 60.5 70.0 79.5
KW 3.0 3.3 3.6 3.8 4.1 4.4 4.6 4.9
70
MBH 11.9 21.4 30.9 40.4 49.8 59.3 68.8 78.3
KW 3.7 4.0 4.3 4.5 4.8 5.1 5.3 5.6
80
MBH 9.6 19.1 28.6 38.0 47.5 57.0 66.5 75.9
KW 4.2 4.4 4.7 5.0 5.2 5.5 5.8 6.0
3000
55
MBH 13.8 23.2 32.7 42.2 51.7 61.1 70.6 80.1
KW 2.9 3.1 3.4 3.7 3.9 4.2 4.5 4.7
70
MBH 12.5 22.0 31.5 40.9 50.4 59.9 69.4 78.8
KW 3.6 3.8 4.1 4.4 4.6 4.9 5.2 5.4
80
MBH 10.3 19.8 29.2 38.7 48.2 57.7 67.1 76.6
KW 4.0 4.3 4.5 4.8 5.1 5.3 5.6 5.9
1. These capacities do not include the supply air blower motor heat. For net capacity, add motor heat, MBh = 3.415 x kW.
TABLE 8: SUPPLY AIR BLOWER PERFORMANCE (BP036 BELT DRIVE) - SIDE DUCT APPLICATION
AIR
FLOW
CFM
AVAILABLE EXTERNAL STATIC PRESSURE - IWG
1
0.2 0.3 0.4 0.5 0.6
RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP
800 - - - - - - 696 357 0.38 743 389 0.42 786 422 0.45
900 - - - 656 353 0.38 706 385 0.41 753 417 0.45 797 450 0.48
1000 - - - 671 376 0.40 722 408 0.44 768 440 0.47 812 473 0.51
1100 634 364 0.39 690 398 0.43 741 431 0.46 787 463 0.50 831 496 0.53
1200 656 389 0.42 712 423 0.45 763 455 0.49 809 488 0.52 853 520 0.56
1300 681 418 0.45 737 452 0.49 787 485 0.52 834 517 0.55 877 550 0.59
1400 707 454 0.49 763 488 0.52 813 520 0.56 860 552 0.59
903 585 0.63
1500 735 496 0.53 791 530 0.57 841 562 0.60 887 594 0.64
931 627 0.67
1600 763 545 0.58 819 579 0.62 870 612 0.66
916 644 0.69 960 677 0.73
1700 793 602 0.65 849 636 0.68
900 669 0.72 946 701 0.75 990 734 0.79
1800 824 667 0.72 880 701 0.75
930 733 0.79 977 765 0.82 1021 798 0.86
1900 855 739 0.79
911 773 0.83 962 806 0.86 1008 838 0.90 1052 871 0.93
2000 887 819 0.88
943 853 0.92 994 886 0.95 1040 918 0.98 1084 951 1.02
AIR
FLOW
CFM
AVAILABLE EXTERNAL STATIC PRESSURE - IWG
1
0.7 0.8 0.9 1.0 1.1
RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP
800 829 457 0.49
872 495 0.53 916 538 0.58 964 586 0.63 1017 642 0.69
900 839 485 0.52
882 524 0.56 927 566 0.61 975 615 0.66 1027 670 0.72
1000 854 508 0.55
897 547 0.59 942 589 0.63 990 638 0.68 1043 693 0.74
1100 874 531 0.57
916 569 0.61 961 612 0.66 1009 660 0.71 1062 715 0.77
1200
896 555 0.60 938 594 0.64 983 636 0.68 1031 685 0.73 1084 740 0.79
1300
920 585 0.63 963 623 0.67 1007 666 0.71 1055 714 0.77 1108 770 0.83
1400
946 620 0.67 989 659 0.71 1034 701 0.75 1082 750 0.80 - - -
1500
974 662 0.71 1017 701 0.75 1061 743 0.80 1109 792 0.85 - - -
1600
1003 712 0.76 1045 750 0.80 1090 793 0.85 - - - - - -
1700
1032 769 0.82 1075 807 0.87 - - - - - - - - -
1800
1063 833 0.89 1106 872 0.94 - - - - - - - - -
1900
1094 906 0.97 - - - - - - - - - - - -
2000 - - - - - - - - - - - - - - -
1. Blower performance includes 1” filters. See STATIC RESISTANCE table for additional applications.
Factory Installed AK74 blower sheave and A39 belt.
AK61 blower sheave and A36 belt - Field installation required.
TABLE 7: BP036-072 HEATING CAPACITIES (CONT.)
Size
(Tons)
Air Over Evaporator
Coil
Capacity
1
& kW
Outdoor Temperature (°F @ 72% RH)
CFM DB (°F) -10 0 10 20 30 40 50 60