York 036-21103-003 Air Conditioner User Manual


 
036-21103-003 Rev. A (0403)
Unitary Products Group 3
1.
TXV = Thermal Expansion Valve kit required. Use 1TV700 series kit.
2.
Single phase units require single phase 2HK heaters — Three phase units require three phase 2HK heaters. (29) indicates 460 volt use only.
3.
G2FD coils available with a factory installed horizontal drain pan. Replace “S” with “H” in the model number.
— = Not Applicable.
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 & 3 Phase
Additional R-22 Charge / Orifice Size for Various Matched Systems
Outdoor Unit (H1RA) 018S78 024S78 030S78 036S78 036S50 048S50 060S50
Unit Orifice(s)
1
51 57 69 71 71 84
Factory R-22 Charge, lbs-oz 3 - 13 3 - 14 3 - 14 4 - 11 4 - 11 7 - 10 9 - 12
Indoor Coil
Coil Orifice
2
System Orifice + Additional Charge, Oz
G2FD024S14,17 61 51 + 0
G2FD030S17 65 57 + 0 69 + 0
G2FD036S17 75 69 + 3 71 + 0 71 + 0
G2FD036S21 75 71 + 2 71 + 2
G2FD042S21 78 71 + 4
G2FD048S21,24 78 84 + 0
G2FD060S24 90 90 + 0
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
3
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED
CFM
NET MBH
KW SEER
SEER/TXV
1
EER
TOTAL SENS.
1 PHASE HRA / NAH
H1RA018S78 N1AHB1293 5,8,10,15,18 17 G2FD024S17 650 18.1 12.9 1.86 -- -- --
H1RA024S78 N1AHB1293 5,8,10,15,18 17 G2FD030S17 850 23.4 16.8 2.87 -- -- --
H1RA030S78
N1AHB1293 5,8,10,15,18 17 G2FD030S17 1000 28.9 20.0 3.45 -- -- --
N1AHB1293 5,8,10,15,18 17 G2FD036S17 1000 29.6 20.6 3.57 -- -- --
H1RA036S78 N1AHB1293 5,8,10,15,18 17 G2FD036S17 1250 33.5 25.2 3.83 -- -- --
3 PHASE HRA / NAH
H1RA036S50
N1AHB1293 5,8,10,15,18 17 G2FD036S17 1200 33.6 24.9 3.81 -- -- --
N1AHB1293 5,8,10,15,18 17 G2FD036S21 1200 34.4 25.5 3.87
N1AHC1693 5,8,10,15,20 21 G2FD042S21 1250 35.1 25.9 3.93
H1RA048S50 N1AHC1693 5,8,10,15,18 21 G2FD048S21 1600 48.8 35.9 4.82 -- -- --
H1RA060S50 N1AHD2093 5,8,10,15,18 24 G2FD060S24 1900 60.5 43.0 6.29 -- -- --
1 PHASE HRA / FRP (SINGLE PHASE)
H1RA018S78 F2RP024N93 5,7.5,10 18 -- 650 18.1 12.9 1.86 -- -- --
H1RA024S78 F2RP024N93 5,7.5,10 18 -- 850 23.4 16.8 2.87 -- -- --
H1RA030S78 F2RP036N93 5,7.5,10,15 21 -- 1000 29.6 20.6 3.57 -- -- --
H1RA036S78 F2RP036N93 5,7.5,10,15 21 -- 1250 34.3 25.6 3.86 -- -- --
3 PHASE HRA / FRP (SINGLE PHASE)
H1RA036S50 F2RP036N93 10,15 21 -- 1200 34.4 25.5 3.87 -- -- --
H1RA048S50 F2RP048N93 10,15 24 -- 1600 48.8 35.9 4.82 -- -- --
H1RA060S50 F2RP060N93 10,15 24 -- 1900 60.5 43.0 6.29 -- -- --
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at
those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the
total electric power
input in watt-hours during the same period.