Windsor 16 Vacuum Cleaner User Manual


 
12 English
Faults
Error Remedy
Machine cannot be started Check if the mains plug is connected
Insufficient quantity of water Check the fresh water level, refill tank if required
Check the hoses for blockages, refill tank if required
Poor vacuum performance Clean the seals between the dirty water tank and cover
and check for tightness, replace if required.
Clean the lint filter
Clean the squeegee blades on the squeegee tool, replace
if required
Check the suction hose for blockages, clean if required
Make sure the suction hose is air-tight, clean if required
Check whether the cover on the dirty water discharge
hose is closed
Check the setting of the squeegee tool.
Poor cleaning result Check the brushes for wear, replace if required
Brushes do not turn Check whether the brushes are blocked by any foreign
substances, remove if required