INSTALLER/CONFIGURATION MENU
To enter the Configuration Menu, SYSTEM must be set to HEAT, COOL or EMER. Press the Menu button for at least 5
seconds. The display will show item #1 in the table below. Press Menu button to advance to the next menu item. Press
or
to change a menu item.
INSTALLER/CONFIGURATION MENU
MENU
SCREEN
NUMBER
HP
MS/
SS
PRESS
BUTTON
DISPLAYED
(FACTORY DEFAULT)
Press
or
to select from listed
options
COMMENTS
01
MENU (Off)
Lk
L Total Keypad lockout
(Not available on earlier models)
02
MENU (000) Lk 001 to 999 Selects Keypad lockout combination number
03
MENU (MS 2) HP 1, HP 2, SS 1 Selects Multi-Stage (MS 2 No Heat Pump),
Heat Pump 1 (HP 1, 1 compressor), or
Single Stage (SS 1), Heat Pump 2 (HP 2,
2 compressor or 2 speed compressor)
04
MENU (GAS) for SS or MS
(ELE) for HP
ELE or
GAS
GAS setting: furnace controls the blower
ELE setting: thermostat controls the blower
05
MENU (0) CS 1, 2, 3, 4, 5, 6 Selects Cool Savings
Value 1 (low) to 6 (high),
Value 0 Disables Feature
06
MENU (ME)
CR Heat
SL, FA Adjustable Anticipation:
Selects heating cycle rate for MS or SS
07
MENU (ME)
CR Cool
SL, FA
Adjustable Anticipation:
Selects cool cycle rate
08
MENU (ME)
CR Heat Pump
SL, FA Adjustable Anticipation (Heat Pump) (only
when heat pump selected in #1)
09
MENU (FA)
CR Emer
SL, FA
SL
Selects the cycle rate for Emergency
mode and Auxiliary stage if Heat Pump
is selected in item 1.
10
MENU (OFF) CL CL On Compressor Lockout Time Delay
11
MENU Heat Auto
Cool Off
Heat Cool Off,
Heat Off with Fan icon,
Heat Off without Fan icon,
Cool Off, Auto Off
Select System Switch Conguration
with Automatic Changeover capability.
12
MENU (On) dL dL OFF Selects Display Light On or OFF
13
MENU 0
(current temperature)
1 HI, 2 HI, 3 HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
Adjustable Ambient Temperature Display
14
MENU
°F °C
Selects Fahrenheit/Celsius
Temperature Display
15
MENU (90) L Heat L 62 to L 89 Selects Limited HEAT Range
16
MENU (45) L Cool L 46 to L 82 Selects Limited COOL Range
17
MS MENU (On) Heat FA OFF Fast Heat option may be disabled by
selecting OFF. NA to SS cong.
NA to Cool only system.
18 HP2
MENU (On) Cool FA OFF Fast Cool option may be disabled by
selecting OFF. NA to SS cong.
NA to Heat only system.
19
MENU (OFF) CA On Selects active Comfort Alert On or OFF.
Requires CA II Module.
(Not available on earlier models)
20
MENU (OFF) Change Filter On Selects Filter Change-out Indicator On or OFF.
21
MENU (200 h) Change Filter 25-1975 h Change Filter time in 25 hour increments. This
menu only appears if On is selected in above.
22
MENU (o) Cool On (b) Heat On Selects operation of the reversing valve termi-
nal (O/B) output as an O or B terminal.