CONFIGURATION MENUCONFIGURATION MENU
CONFIGURATION MENUCONFIGURATION MENU
CONFIGURATION MENU
Non- Displayed Press or
Program- Program- Press (Factory to select from
mable mable Button Default) listed options Comments
1 1 MS 2 HP 1, HP 2, SS 1 Selects Multi-Stage (MS 2, No Heat Pump), Heat Pump 1
(HP 1, 1 compressor), Heat Pump 2 (HP 2, 2 compressor
or 2 speed compressor), or Single Stage.
22
(ELE) GAS GAS setting: furnace controls blower.
ELE setting: thermostat controls blower.
33
Days, (
77
77
7)
P P
P P
P
55
55
5-1-1 or
00
00
0 Programs per week. (0 = non-programmable)
4NA
PSPS
PSPS
PS (
44
44
4)
22
22
2 Program periods per day.
4 = Morning, Day, Evening, Night
2 = Day, Night
54
Cool-Off- Cool-Off-Heat, System switch configuration in non heat pump mode.
Heat-Auto Off-Heat, Cool-Off
Cool-Off-Heat- Cool-Off-Heat-Emer, System switch configuration, heat pump mode.
Emer-Auto Off-Heat-Emer, Cool-Off
6NA
E E
E E
E (On)
OFFOFF
OFFOFF
OFF Selects Energy Management Recovery, E (with programming option on)
75
Cr, Heat (FA) SL Selects Adjustable Anticipation, cycle rate, Heat
86
Cr, Cool (FA) SL Selects Adjustable Anticipation, cycle rate, Cool
97
Cr/AU, Emer (FA) SL Selects Adjustable Anticipation, cycle rate auxiliary, (This item is
only to appear if HP 1 or HP 2 is selected above).
10 8
CL CL
CL CL
CL (OFF) On Selects Compressor Lockout.
11 9
dL dL
dL dL
dL (On) OFF Selects Continuous Display backlight & intensity.
12 10
dL dL
dL dL
dL (LO) HI Selects Backlight Intensity.
13 11
0 4, LO to 4, HI Selects Adjustable Ambient Temperature Display [range -4 (LO) to
+4 (HI)].
14 12
°
FF
FF
F °
CC
CC
C Selects °F/°C Display (temperature units in Fahrenheit or Celsius).
15 13
b b
b b
b (On) OFF Selects audible Beeper On/Off.
16 14
dS dS
dS dS
dS (On) OFF Selects Daylight Saving Time calculation.
17 15
ASAS
ASAS
AS, Heat (On) OFF Selects Automatic Schedule for comfort temperature Programming,
heat mode.
18 16
ASAS
ASAS
AS, Cool (On) OFF Selects Automatic Schedule for comfort temperature Programming,
cool mode.
19 17
CSCS
CSCS
CS, (OFF) 1-2-3-4-5-6 Selects Cool Saving Feature & amount.
Cool Savings
20 18
HLHL
HLHL
HL, Heat (99) 62-98 TEMPERATURE LIMIT, HEAT (max. heat set point).
21 19
LLLL
LLLL
LL, Cool (45) 46-82 TEMPERATURE LIMIT, COOL (min. cool set point).
22 20
OFF,
L L
L L
L (total),
P P
P P
P (partial), Selects Keypad Lockout.
Keypad LockoutKeypad Lockout
Keypad LockoutKeypad Lockout
Keypad Lockout
Temperature LimitTemperature Limit
Temperature LimitTemperature Limit
Temperature Limit
(limited temperature range)
000 001-999 Selects Keypad Lockout Combination (active only if keypad Lockout
is selected).
23 21
FS, Heat (On) OFF Fast second stage of heat (not available if SS1 is selected above).
24 22
FS, Cool (On) OFF Fast second stage of cool (not available if SS1 or HP1 is selected
above).
25 23
Remote (OFF) On Remote temperature sensor, enable/disable.
In, Remote Outdoor Remote Remote temperature sensor (Indoor/Outdoor).
LS (On) OFF Local temp. Sensor enable/disable (only when Indoor Remote is
selected On).
26 24
dF dF
dF dF
dF (5) 5-50 Selects Dual Fuel Feature & set point (in Fahrenheit) (applicable only
when HP1 or HP2 is selected).
Cd Cd
Cd Cd
Cd (60) 0-99 Selects Compressor delay in seconds (only when
dF dF
dF dF
dF is selected >5).
27 25
Change Filter On Selects Change filter feature
(OFF)
200 Hours 25-1975 (in increments Change filter, duration hours.
of 25 hours)
INSTALLER/CONFIGURATION MENUINSTALLER/CONFIGURATION MENU
INSTALLER/CONFIGURATION MENUINSTALLER/CONFIGURATION MENU
INSTALLER/CONFIGURATION MENU
To enter the menu: Press the
MenMen
MenMen
Men
u u
u u
u touch key. Press and hold for 5 seconds the
Installer ConfigInstaller Config
Installer ConfigInstaller Config
Installer Config touch key. This displays
menu item #1 in the table below. Press
to advance to the next menu item or to return to a previous menu item. Press
or to change a menu item.
Menu
Reference
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27