White Rodgers 1F95W-80 Thermostat User Manual


 
16
increase the cycle time. If the heat cycles
are too long, press
TIME
BACK
to decrease the
cycle time. To set cooling anticipation, press
SET
CLOCK
and
ADV
DAY
at the same time again. The
display will show COOL 14 (factory
preprogrammed cooling anticipation). Press
TIME
FWD
or
TIME
BACK
to adjust anticipation. Press
RUN
PRGM
to return to your program.
LOW BATTERY INDICATOR — The word
BATTERY will flash on the display if the 9
volt alkaline battery is low and should be
replaced.
AUDIO PROMPTING — Each time you
press a button, the thermostat will beep (this
feature works only when the thermostat is
attached to the wall and 24 VAC power is
present to the thermostat).
BACKLIT DISPLAY — When you press
any button on the thermostat, the display is
lit for approximately eight seconds (this fea-
ture works only when the thermostat is
attached to the wall and 24 VAC power is
present to the thermostat).
COMPRESSOR SHORT CYCLE PROTEC-
TION — To protect your compressor from
potential damage due to rapid cycling, this
thermostat has a built-in delay of 5 minutes
between cooling cycles. The following may
cause a time delay in COOL:
a) Return of power after a power outage.
b) Pressing
SYSTEM
HEAT - OFF - COOL - AUTO
to change operating
modes.
c) Pressing or , creating a call
for COOL too soon after a previous call.