Whirlpool WHES48 Water System User Manual


 
19
Customizing Features / Options
SET CLEAN FEATURE
The Clean Feature with Sediment Guard technology
is beneficial on water supplies containing ferrous
(clear water) iron. The default setting is OFF. When
set to ON, an additional backwash and fast rinse
cycle will occur first, preceding the normal regenera-
tion sequence. This provides extra cleaning of the
resin bed before it is regenerated with the salt brine.
To conserve water set this feature OFF if your water
supply does not contain iron or sediments.
To set this feature:
1. Press the SETUP button on the softener status
screen.
2. Press the LEFT (
) button twice to display the
screen shown in Figure 57.
FIG. 59
FIG. 60
FIG. 57
3. Press the ADVANCED SETUP button. The display
will change to the following screen.
4. Press the ADDITIONAL FEATURES button to dis-
play the screen shown in Figure 59.
FIG. 58
5. Press the SET CLEAN FEATURE button and the
display will change to show the Set clean feature
screen (See Figure 60).
continued
SET CLEAN TIME
The length of the Clean Feature with Sediment Guard
technology can be adjusted, from 1 to 30 minutes.
The default value for this feature is 7 minutes.
To change the clean time:
1. Press the SETUP button on the softener status
screen.
2. Press the LEFT (
) button twice to display the
screen shown in Figure 57.
3. Press the ADVANCED SETUP button to display the
screen shown in Figure 58.
4. Press the ADDITIONAL FEATURES button to dis-
play the screen shown in Figure 59.
5. Press the RIGHT (
) button to display the screen
shown in Figure 61.
FIG. 61
FIG. 62
6. Press the SET CLEAN TIME button and the dis-
play will change to show the Set clean time
screen (See Figure 62).
7. Press the UP (
) or DOWN ( ) buttons to set the
clean time in 1 minute increments. Hold the button
down to rapidly advance. When the desired clean
time is shown, press the RETURN (
) button.
8. To return to the softener status screen, press the
RETURN (
) button three times.
6. Press the button next to ON to enable this feature
(or OFF to disable it) and then press the RETURN
(
) button.
7. To return to the softener status screen, press the
RETURN ( ) button three times.