Whirlpool WHES48 Water System User Manual


 
16
Programming Your E-Z Touch Water Softener
SETUP BUTTON
The SETUP button on the softener status screen is
used to set items of basic operating information:
=Set current time
=Set water’s hardness
=Set recharge time
=Set water’s iron level
=Advanced setup (Accesses more items that can
be set. These are described starting on Page 19)
=Set language
FIG. 43
SET TIME
When the softener’s electronic control is first powered
up, the setup procedure prompts you to set the cur-
rent time (See Page 12). To change the time at a
later date, such as after a long power loss:
1. Press the SETUP button on the softener status
screen (See Figure 42).
3. Press the DOWN ( ) or UP ( ) buttons to set the
current time. Hold the button down to rapidly
advance. Be sure AM or PM is correct (unless sof-
tener is set for a 24-hour clock). When the current
time is shown, press the RETURN (
) button.
4. To return to the softener status screen, press the
RETURN (
) button.
FIG. 44
FIG. 41
FIG. 39
FIG. 40
SCHEDULE A RECHARGE
To schedule a recharge for the next preprogrammed
recharge time (2:00 a.m., or as set on Page 15):
1. Press the RECHARGE button at the bottom of the
softener status screen (See Figure 37).
FIG. 37
2. The display will change to show the following
screen.
3. Press the LEFT (
) button. The display will change
to show the following screen.
FIG. 38
4. Press the SCHEDULE RECHARGE button. The
display will change to show the screen in Figure 40.
5. Press the button next to ON, then press the
RETURN (
) button. The display will go back to
the screen shown in Figure 39.
6. To return to the softener status screen, press the
RETURN ( ) button.
2. Press the SET TIME button (See Figure 43) and
the display will change to show the Set time
screen (See Figure 44).
FIG. 42