Weil-McLain CGS-4E Boiler User Manual


 
Part number 550-110-282/1108
36
GOLD
CGs-4E Gas-Fired Water Boiler — Boiler Manual
Addendum Instruction for the
Commonwealth of Massachusetts
This addendum must only be used by a
qualified heating installer/service technician.
Read these instructions completely before
beginning the installation. Failure to comply
could result in severe personal injury, death
or substantial property damage.
(a) For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those
ownedoroperatedbytheCommonwealthandwherethe
side wall exhaust vent termination is less than seven (7) feet
above finished grade in the area of the venting, including but
not limited to decks and porches, the following requirements
shall be satisfied:
1.
INSTALLATION OF CARBON MONOXIDE DETEC-
TORS
.Atthetimeofinstallationofthesidewallhorizon-
tal vented gas fueled equipment, the installing plumber
or gas fitter shall observe that a hard wired carbon
monoxide detector with an alarm and battery back-up
is installed on the floor level where the gas equipment is
to be installed. In addition, the installing plumber or gas
fitter shall observe that a battery operated or hard wired
carbon monoxide detector with an alarm is installed on
each additional level of the dwelling, building or struc-
ture served by the side wall horizontal vented gas fueled
equipment. It shall be the responsibility of the property
owner to secure the services of qualified licensed profes-
sionals for the installation of hard wired carbon monoxide
detectors
a. In the event that the side wall horizontally vented gas
fueled equipment is installed in a crawl space or an
attic, the hard wired carbon monoxide detector with
alarm and battery back-up may be installed on the
next adjacent floor level.
b. In the event that the requirements of this subdivision
can not be met at the time of completion of installa-
tion, the owner shall have a period of thirty (30) days
to comply with the above requirements; provided,
however, that during said thirty (30) day period, a
battery operated carbon monoxide detector with an
alarm shall be installed.
2.
APPROVED CARBON MONOXIDE DETECTORS.Each
carbon monoxide detector as required in accordance with
theaboveprovisionsshallcomplywithNFPA720andbe
ANSI/UL2034listedandIAScertied.
3.
SIGNAGE.Ametalorplasticidenticationplateshall
be permanently mounted to the exterior of the build-
ing at a minimum height of eight (8) feet above grade
directly in line with the exhaust vent terminal for the
horizontally vented gas fueled heating appliance or
equipment. The sign shall read, in print size no less than
one-half(1/2)inchinsize,“GASVENTDIRECTLYBE-
LOW.KEEPCLEAROFALLOBSTRUCTIONS.”
4.
INSPECTION. The state or local gas inspector of the
side wall horizontally vented gas fueled equipment shall
not approve the installation unless, upon inspection,
the inspector observes carbon monoxide detectors and
signage installed in accordance with the provisions of
248CMR5.08(2)(a)1through4.
(b)
EXEMPTIONS: The following equipment is exempt from
248CMR5.08(2)(a)1through4:
1. TheequipmentlistedinChapter10entitled“Equipment
NotRequiredToBeVented”inthemostcurrentedition
ofNFPA54asadoptedbytheBoard;and
2. ProductApprovedsidewallhorizontallyventedgasfueled
equipment installed in a room or structure separate from
the dwelling, building or structure used in whole or in
part for residential purposes.
(c)
MANUFACTURER REQUIREMENTS — GAS EQUIPMENT
VENTING SYSTEM PROVIDED
. When the manufacturer of
ProductApprovedsidewallhorizontallyventedgasequip-
ment provides a venting system design or venting system
components with the equipment, the instructions provided
by the manufacturer for installation of the equipment and
the venting system shall include:
1. Detailedinstructionsfortheinstallationoftheventing
system design or the venting system components; and
2. Acompletepartslistfortheventingsystemdesignor
venting system.
(d)
MANUFACTURER REQUIREMENTS — GAS EQUIPMENT
VENTING SYSTEM NOT PROVIDED
. When the manufac-
turerofaProductApprovedsidewallhorizontallyventedgas
fueled equipment does not provide the parts for venting the
uegases,butidenties“specialventingsystems”,thefollow-
ing requirements shall be satisfied by the manufacturer:
1. Thereferenced“specialventingsystem”instructionsshall
be included with the appliance or equipment installation
instructions; and
2. The“specialventingsystems”shallbeProductApproved
bytheBoard,andtheinstructionsforthatsystemshallin-
clude a parts list and detailed installation instructions.
(e)AcopyofallinstallationinstructionsforallProductApproved
side wall horizontally vented gas fueled equipment, all venting
instructions, all parts lists for venting instructions, and/or all
venting design instructions shall remain with the appliance
or equipment at the completion of the installation.