Weber Summit Built-In NG Side Burner Burner User Manual


 
8
GAS INSTRUCTIONS

TOSIDE
BURNER
TOREGULATOR
TOPVIEW

Check:
1) Corrugated gas line-to-Accessory “T” Connection.
2) Main gas Supply to regulator
ƽ WARNING: If there is a leak a connection(1), retighten
the fi tting with a wrench and recheck for leaks with
soap and water solution.
If a leak persists after retightening the fi tting, turn OFF
the gas. DO NOT OPERATE THE GRILL. Contact the Cus-
tomer Service Representative in your region using the
contact information sheet provided with your manual.
Check:
When leak checks are complete, turn gas supply OFF at the source and rinse
connections with water.
SIDE BURNER LIGHTING INSTRUCTIONS
ƽ DANGER
Failure to open the lid while igniting the side
burner, or not waiting 5 minutes to allow the
gas to clear if the side burner does not light,
may result in an explosive fl ame-up which can
cause serious bodily injury or death.
LIGHTING THE SIDE BURNER
1) Open the side burner lid.
2) Check that the side burner valve is turned OFF. (Push the knob down
and turn clockwise to ensure it is in the off position.).
3) Turn the gas supply valve on.
4) Push down and turn the side burner control valve to START/HI.
5) Push igniter button and hold until burner ignites. You will hear the igniter
sparking.
ƽ CAUTION: Side burner fl ame may be diffi cult to see on
a bright sunny day.
ƽ WARNING: If the side burner does not light:
1) Turn OFF the side burner control valve.
2) Wait 5 minutes to let the gas clear before you try
again or try to light with a match.
