Weber Summit Built-In NG Side Burner Burner User Manual


 
7
Regulator
Hard piped
gas supply
top view
Figure 1
Cap
(Optional
Side Burner)
Regulator
to side burner
Hard piped
gas supply
top view
Figure 2
CONNECT GAS SUPPLY
1) Uncap the fl are fi tting from the optional side burner connection located
at regulator.
Note: You must connect your side burner to a Weber
®
approved regulator
(part number #62434) located at main gas supply. If you do not use a
Weber
®
approved regulator the Warranty on the Summit
®
Built-In Side
Burner will be voided. If you have any questions, contact Customer Service
at 1-800-446-1071.
2) Connect the corrugated gas line to the side burner Connection.
GAS INSTRUCTIONS
ƽ WARNING: You should check for gas leaks every time
you disconnect and reconnect a gas fi tting.
Note - All factory-made connections have been thoroughly checked for gas
leaks. As a safety precaution however, you should recheck all fi ttings for leaks
before using your Summit
®
Built-In side burner. Shipping and handling may
loosen or damage a gas fi tting.
You will need: a soap and water solution, and a rag or brush to apply it.
Turn on gas supply.
Check for leaks by wetting the connections with the soap and water solution
and watching for bubbles. If bubbles form or if a bubble grows, there is a leak.
Note - Since some leak test solutions, including soap and water, may be
slightly corrosive, all connections should be rinsed with water after checking
for leaks.
ƽWARNING: Do not ignite burners when leak checking.
TEST CONNECTIONS
All connections and joints must be thoroughly tested for leaks in accordance
with local codes and all listed procedures in the latest edition of the National
Fuel Gas Code ANSI Z223.1/NFPA 54.
ƽ DANGER
Do not use an open fl ame to check for gas
leaks. Be sure there are no sparks or open
ames in the area while you check for gas
leaks. This will result in a fi re or explosion
which can cause serious bodily injury or
death, and damage to property.
TEST CONNECTIONS
All connections and joints must be thoroughly tested for leaks in accordance
with local codes and all listed procedures in the latest edition of AS5601/
AG601.
ƽ DANGER
Do not use an open fl ame to check for gas leaks. Be sure
there are no sparks or open fl ames in the area while you
check for gas leaks. This will result in a fi re or explosion
which can cause serious bodily injury or death, and
damage to property.