4
LOCATING YOUR BUILT-IN SIDE BURNER
When determining a suitable location for your Built-In Side Burner installa-
tion, give attention to concerns such as exposure to wind, proximity to traffi c
paths, and keeping any gas supply lines as short as possible. Never locate
the Summit
®
Built-In Side Burner in a garage, breezeway, shed, under an
unprotected overhang, or other enclosed area. Locate the Side Burner and
structure so there is enough room to safely evacuate the area in case of a
fi re.
CLEARANCE FROM COMBUSTIBLE SURFACES OR
STRUCTURES
ƽ WARNING: Clearance from the outside walls of
the sides and back of the LP Tank Cabinet must be a
minimum of 24 inches any surface. Refer to “Typical Gas
Supply Installation” before starting installation.
ƽ WARNING: The structure, “island” counter tops and
adjacent work areas for the LP Tank Cabinet installation
must be built from noncombustible materials only.
NOTE: If you have questions on what materials are considered
noncombustible, contact you local building supplier or fi re department.
BUILT-IN SRUCTURE CUTOUT DIMENSIONS
All dimensions are to fi nished surfaces.
Any Surface
Any Surface
24 inches Any Surface
24 inches
24 inches
Note: For a countertop
treatment: Recommended
3/4 inch overhang. Notch
front edge for frame to
fully slide in.
Side
Burner
24 inches min.
for lid clearance
ƽWARNING: All counter top fi nished surfaces must be
constructed of a noncombustible material.
GAS INSTRUCTIONS
Side Burner
Cut out Dimensions Tolerances
A
10
1
2
"+
1
/
4
" -
1
/
4
"
B
3
3
/
4
"+
1
/
4
" -
1
/
4
"
C
16
1
/
4
"+
1
/
4
" -
1
/
4
"