Weber 89796 Burner User Manual


 
WWW.WEBER.COM
®
13
IGNITER
If the Ignition system fails to ignite the side burner, light the burner with a match.
Check that both ignition wires(1,2) are attached properly.
You should hear the igniter sparking.
If the ignition system still fails to light, contact the Customer Service
Representative in your area using the contact information on our web site. Log
onto www.weber.com
®
.
REPLACE IGNITER BATTERIES
Parts required: 1 AA alkaline battery per igniter.
Unscrew igniter button from front of control panel. Remove igniter button and contact
spring. Remove old battery and replace with a new AA
alkaline battery. Positive end (1) of battery faces inward as shown in illustration. Replace
spring contact (2) and screw igniter button (3) back onto battery compartment.

MANUALLY LIGHTING THE SIDE BURNER
ƽ DANGER
Failure to open the lid while igniting the side burner, or not
waiting 5 minutes to allow the gas to clear if the side burner
does not light, may result in an explosive flame-up which can
cause serious bodily injury or death.
1) Open the side burner lid.
2) Check that the side burner valve is turned OFF. (Push the knob down and turn
clockwise to ensure that it is in the off position.)
ƽ WARNING: The burner control knob must be in the OFF
position before turning on the liquid propane cylinder
valve. If it is not in the OFF position, when you turn on the
LP cylinder valve, the “excess gas flow control” feature
will activate, limiting the flow of gas from the LP cylinder.
If this should occur, turn OFF the LP tank valve and burner
control knobs. Then start over.
3) Turn the LP tank valve on (turn counter-clockwise).
4) Put match in a match holder and strike match.
5) Push down and turn the side burner control valve to START/HI.
6) Hold match holder and lit match by right side of side burner.
7) Push igniter button and hold until burner ignites. You will hear the igniter sparking.
ƽ CAUTION: Side burner flame may be difficult to see on a
bright sunny day.
ƽ WARNING: If the side burner does not light:
1) Turn OFF the side burner control valve.
2) Wait 5 minutes to let the gas clear before you try again
or try to light with a match.
MAINTENANCE