Check:
1) Corrugated gas line-to-Accessory “T” Connection
2) Regulator-to-Cylinder connection.
ƽ WARNING: If there is a leak at connection (1), retighten
the fitting with a wrench and recheck for leaks with soap
and water solution. If a leak persists after re-tightening the
fitting, turn OFF the gas. DO NOT OPERATE THE GRILL.
Contact Customer Service 1-800-446-1071.
Check:
3) “T” Connection-to-Hose connections.
4) The hose-to-Regulator connection.
ƽ WARNING: If there is a leak at connections (2,3, or 4),
turn OFF the gas. DO NOT OPERATE THE GRILL. Contact
Customer Service 1-800-446-1071.
When leak checks are complete, turn gas supply OFF at the source and rinse
connections with water.
(2)
(4)
(3)
(1)
SAFE HANDLING TIPS FOR LIQUID PROPANE GAS
CYLINDERS
Liquid Propane (LP) gas is a petroleum product as are gasoline and natural gas.
LP gas is a gas at regular temperatures and pressures. Under moderate pressure,
inside a cylinder, LP gas is a liquid. As the pressure is released, the liquid readily
vaporizes and becomes gas.
LP gas has an odor similar to natural gas. You should be aware of this odor.
LP gas is heavier than air. Leaking LP gas may collect in low areas and prevent
dispersion.
To fill, take the LP cylinder to a gas propane dealer, or look up “gas-propane” in
the phone book for other sources of LP gas.
ƽ WARNING: We recommend that your LP cylinder be filled
at an authorized LP gas dealer, by a qualified attendant,
who fills the tank by weight. IMPROPER FILLING IS
DANGEROUS.
Air must be removed from a new LP cylinder before the initial filling. Your LP
dealer is equipped to do this.
The LP cylinder must be installed, transported and stored in an upright position.
LP cylinders should not be dropped or handled roughly.
Never store or transport the LP cylinder where temperatures can reach 125° F
(too hot to hold by hand - for example: do not leave the LP cylinder in a car on a
hot day).
Note: A refill will last about 18-20 hours of cooking time at normal use. The fuel scale
will indicate the propane supply so you can refill before running out. You do not have
to run out before you refill.
Treat “empty” LP cylinders with the same care as when full. Even when the LP
tank is empty of liquid there still may be gas pressure in the cylinder. Always
close the cylinder valve before disconnecting.
ƽ CAUTION: Place dust cap on cylinder valve outlet whenever
the cylinder is not in use. Only install the type of dust cap
on the cylinder valve outlet that is provided with the cylinder
valve. Other types of caps or plugs may result in leakage of
propane.
Do not use a damaged LP cylinder. Dented or rusty LP cylinders or LP cylinders
with a damaged valve may be hazardous and should be replaced with a new one
immediately.
Liquid Propane (LP) Cylinder(s)
The joint where the hose connects to the LP cylinder must be leak tested each
time the LP cylinder is reconnected. For example, test each time the LP cylinder is
refilled.
OPERATING