Weber 89796 Burner User Manual


 
12
WWW.WEBER.COM
®
1) Open the side burner lid.
2) Check that the side burner valve is turned OFF. (Push knob in and turn clockwise
to ensure that it in the off position.)
ƽ WARNING:
The burner control knob must be in the OFF position before
turning on the liquid propane cylinder valve. If it is not in the
OFF position, when you turn on the LP cylinder valve, the
“excess gas flow control” feature will activate, limiting the
flow of gas from the LP cylinder. If this should occur, turn
OFF the LP tank valve and burner control knobs. Then start
over.

Be sure the regulator is mounted with the small vent hole pointed downward so
that it will not collect water. This vent should be free of dirt, grease, bugs etc.
The gas connections supplied with your Weber
®
gas barbecue have been
designed and tested to meet 100% CSA and ANSI requirements.
ƽ WARNING: Replacement LP tanks must match the regulator
connection supplied with this barbecue.
LIQUID PROPANE CYLINDER REQUIREMENTS
Check to be sure cylinders have a D.O.T. certification (1), and date tested (2) is
within five years. Your LP gas supplier can do this for you.
All LP tank supply systems must include a collar to protect the cylinder valve.
The LP cylinder must be a 20-lb. size approximately (18¼ inches high, 12¼
inches in diameter).
The cylinder must be constructed and marked in accordance with the
Specifications for LP - Gas Cylinders of the U.S. Department of Transportation
(D.O.T.) or the National Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres and Tubes or Transportation of Dangerous Goods; and Commission, as
applicable.
IN CANADA
LIQUID PROPANE CYLINDER REQUIREMENTS
Note: Your retailer can help you match a replacement tank to your barbecue.
The LP cylinder must be constructed and marked in accordance with the
specifications for LP gas cylinders, T.C.
DOT 4BA240
00/02
(1)
(2)
SIDE BURNER LIGHTING INSTRUCTIONS
ƽ DANGER
Failure to open the lid while igniting the side burner, or not
waiting 5 minutes to allow the gas to clear if the side burner
does not light, may result in an explosive flame-up which can
cause serious bodily injury or death.
3) Turn the LP tank valve on (turn counter-clockwise).
4) Push in and turn the side burner control valve to START/HI.
5) Push igniter button and hold until burner ignites. You will hear the igniter sparking.
ƽ CAUTION: Side burner flame may be difficult to see on a
bright sunny day.
ƽ WARNING: If the side burner does not light:
1) Turn OFF the side burner control valve.
2) Wait 5 minutes to let the gas clear before you try again
or try to light with a match.
TO EXTINGUISH
Push down and turn each burner control knob clockwise to the OFF position. Turn gas
supply OFF at the source.