Webasto 300.102 Water Heater User Manual


 
WEBASTO THERMO 300 4TECHNICAL DATA
4-1
4. Technical Data
4.1 General Information
Where no threshold values are specified, technical data are understood to include standard tolerances for heater
units of ± 10% at ambient temperature of + 20 °C (+ 68 °F) and at nominal voltage.
Electrical components:
Control unit, fan and circulation pump motors, solenoid valve, igniter box, heater cartridge, nozzle pre-heater and
timer are 24V components. Temperature limiter, flame sensor, temperature sensor and switches are voltage
independent components.
Heater
Type
Mark of conformity
Heater design principle
Heat output kW/h (BTU/h)
Fuel
Fuel consumption kg/h (US. Gal/h)
Rated nominal voltage V
Operating voltage V
Nominal power consumption W
(without circulation pump)
Permissible operating ambient °C (°F)
temperature range
(heater, control unit, circulation pump)
Permissible storage temperature °C (°F)
Permissible operating pressure bar (psi)
of coolant system
Heat exchanger capacity l (US. Gal)
Minimum capacity of circuit l (US. Gal)
CO
2
in exhaust at nominal voltage Vol.-%
Dimensions of heater length
width
height
Weight kg (lb.)
Thermo 300
DW 300.
~ S229
High pressure fuel atomizing nozzle
30 (104,000)
Diesel #1, Diesel #2, Arctic grade and Kerosene
3.3 (1.2)
24
20 ... 28
110
- 40 ... + 60 (- 40 … + 140)
+ 85 max. (+ 185)
0.4 ... 2.0 (06 … 29)
1.8 (0.475)
10.00 (2.64)
10 + 0.5 related to 500 m above S.L.
610 mm (24.01 in.)
246 mm (9.69 in.)
220 mm (8.66 in.)
19 (41.88)
NOTE:
The allocation of circulation pumps to heater units must be in accordance with coolant resistances.
4.2 Thermo 300 Heater Data
Table 4-1: Thermo 300 Heater Data