Vanguard Heating 107156-01E.pdf Indoor Fireplace User Manual


 
107156-01E
For more information, visit www.desatech.com
For more information, visit www.desatech.com
9
9
Figure 9 - Placing Hearth Base Accessory Against Wall
Electrical Outlet
Hearth Base
Rigid Pipe and
Gas Shutoff Valve
Gas Line
Access Hole
INSTALLATION
Continued
Figure 10 - Installing Cabinet Mantel
Cabinet
Mantel
1. Assemble cabinet mantel, hearth base, and trim accessories.
Assembly instructions are included with each accessory.
2. When installing blower, install a properly grounded, 120 volt
three-prong electrical outlet at fireplace location if an outlet is
not there. If possible, locate outlet so cabinet mantel will cover
it when installed (see Figure 9).
3. Install gas piping to fireplace location. This installation includes
an approved flexible gas line (if allowed by local codes) after
the equipment shutoff valve. The flexible gas line must be the
last item installed on the gas piping. See Installing Gas Piping
to Fireplace Location, page 11.
4. Place hearth base accessory against wall at installation loca-
tion. Cut an access hole in hearth top to run gas line to fire-
place (see Figure 9). Make sure to locate access hole so cabi-
net mantel will cover it when installed.
Note:
You can secure
base to floor using wood screws. Countersink screw heads and
putty over.
5. Route gas line through access hole in hearth base.
6. Center cabinet mantel on hearth base (see Figure 10). Make
sure mantel is flush against wall.
7. Break off nailing flanges (see Figure 11) with hammer or pliers.
8. Place cardboard or other protective material on top of hearth
base. Carefully set fireplace on protective material, with back
of fireplace inside mantel opening.
9. If blower is installed, route blower electrical cord through ac-
cess holes in either side of fireplace.
Note:
Bushing may be
moved if necessary. Plug electrical cord into electrical outlet.
10. Carefully insert fireplace into cabinet mantel (Figure 12). Be
careful not to scratch or damage hearth base, cabinet mantel,
or any laminate trim on hearth base. Remove protective mate-
rial from top of hearth base and from front of fireplace (if any).
Note:
You can secure fireplace to hearth or floor. Open lower
louver. Locate screw holes in bottom of base. Tighten wood
screws through these holes and into hearth or floor.
11. Attach gas line from fireplace gas regulator to gas supply. See
Connecting Fireplace to Gas Supply, page 12.
12. Check all gas connections for leaks. See Checking Gas Connec-
tions, pages 12 and 13.
Figure 12 - Inserting Fireplace Into Cabinet Mantel
Figure 11 - Location of Nailing Flanges
Nailing
Flanges
INSTALLATION
Conventional Fireplace Installation (Cont.)