Vanguard Heating 107156-01E.pdf Indoor Fireplace User Manual


 
107156-01E
For more information, visit www.desatech.com
For more information, visit www.desatech.com
7
7
INSTALLATION
Continued
Note:
Your fireplace is designed to be used in zero clearance
installations. Wall or framing material can be placed directly against
any exterior surface on the rear, sides, or top of your fireplace,
except where standoff spacers are integrally attached. If standoff
spacers are attached to your fireplace, these spacers can be placed
directly against wall or framing materials.
Use the dimensions shown for rough openings to create the easiest
installation (see Built-In Fireplace Installation, page 10).
CAUTION: This fireplace creates warm air cur-
rents. These currents move heat to wall surfaces next
to fireplace. Installing fireplace next to vinyl or cloth
wall coverings or operating heater where impurities
(such as, but not limited to, tobacco smoke, aromatic
candles, cleaning fluids, oil or kerosene lamps, etc.)
in the air exist, may discolor walls or cause odors.
WARNING: A qualified service person must in-
stall fireplace. Follow all local codes.
WARNING: Never install the fireplace
in a bedroom or bathroom
in a recreational vehicle
where curtains, furniture, clothing, or other flam-
mable objects are less than 42 inches from the
front, top, or sides of the fireplace
in high traffic areas
in windy or drafty areas
WARNING: Models VSGF28PTC
have a three-prong,
grounded electrical plug. This plug helps protect you
against electrical shock. Only connect plug to a
properly grounded, three-prong receptacle. Do not
cut or remove the grounding prong from this plug.
NOTICE: This heater is intended for use as supple-
mental heat. Use this heater along with your primary
heating system. Do not install this heater as your
primary heat source. If you have a central heating
system, you may run systems circulating blower
while using heater. This will help circulate the heat
throughout the house. In the event of a power outage,
you can use this heater as your primary heat source.
Figure 5 - Installing Hood
INSTALLING HOOD
Install hood to rail already installed in fireplace as shown in Figure 5.
Use 3 Phillips screws provided.
Screw
Hood
Rail
IMPORTANT:
Vent-free heaters add moisture to the air. Although
this is beneficial, installing fireplace in rooms without enough
ventilation air may cause mildew to form from too much moisture.
See Air for Combustion and Ventilation, pages 4 through 6.
IMPORTANT:
Make sure the fireplace is level. If fireplace is not
level, log set will not work properly.
CHECK GAS TYPE
Use only propane/LP gas. If your gas supply is not propane/LP gas,
do not install fireplace. Call dealer where you bought fireplace for
proper type fireplace.
ELECTRICAL HOOKUP
(Model VSGF28PTC or VSGF28PVA with GA3750
or GA3650T Series Blower)
This fireplace has a blower assembly with an electrical cord. The
electrical cord is five feet in length. You must locate fireplace within
reach of a 120-volt grounded electrical outlet. If not, you must install
an electrical outlet within reach of fireplace power cord.
The GA3555
outlet accessory may be used for built-in installation when a blower
is installed. This same information applies if installing optional
blower accessories to Model VSGF28PVA.
INSTALLATION
Check Gas Type
Electrical Hookup
Installing Hood