Universal Electronics 975 Thermostat User Manual


 
16
Step Press Button(s) Displayed (Factory Default) Press or to select: COMMENTS
1 EMR
(ON)
OFF
2 SET CYCL HEAT
(05)
02 - 40
Adjusts heat anticipation value (2 through 40)
3 SET CYCL COOL
(14)
09 - 40
4 COOL FAN DELA OFF
(01)
01 - 127
5 COOL FAN DELA ON
(04)
01 - 05
6 COMP LOCK
(ON)
OFF
7 SYSTEM
(HEAT-OFF-COOL-AUTO)
HEAT-OFF,
COOL-OFF,
HEAT-OFF-COOL
Selects system switch choices for heat only,
cool only, heat/cool or automatic changeover
Selects EMR option ON or OFF
Adjusts cool anticipation value (9 through 40)
Adjusts cool fan-off delay (1 through 127 sec.)
Selects compressor lockout ON or OFF (see NOTE)
Adjusts cool fan-on delay (1 through 5 sec.)
TIME
FWD
TIME
FWD
TIME
FWD
TIME
FWD
TIME
FWD
TIME
FWD
TIME
FWD
CONFIGURATION MENUCONFIGURATION MENU
CONFIGURATION MENUCONFIGURATION MENU
CONFIGURATION MENU