SPECIFICATIONS
Natural Gas
Manifold Pressure Setting 4" w.c.
Gas Inlet Pressure Maximum 10-1/2" w.c.
Minimum 5" w.c.
Gas Rate
Number
Model Number Type Max BTU/Hr Min BTU/Hr of Burners
VF30IN Manual 30,000 16,000 1
Propane / LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c.
Manifold Pressure Setting 10" w.c.
Gas Inlet Pressure Maximum 13" w.c.
Minimum 11" w.c.
Gas Rate
Number
Model Number Type Max BTU/Hr Min BTU/Hr of Burners
VF30IL Manual 30,000 16,000 1
GLOVES ARE RECOMMENDED WHEN HANDLING CERAMIC FIBER LOGS
TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS. LOGS ARE FRAGILE,
HANDLE WITH CARE.
CONTENTS
Carefully inspect the contents for shipping damage and immediately inform your dealer if any damage is found.
CAUTION
VF30IN and VF30IL Vent-free Gas Room Heaters
1. Owner's manual.
2. Log box containing four (4) fiber ceramic logs, refer to installation instructions.
3. Vent-free gas heater.
CHECK THAT ALL LISTED PARTS HAVE BEEN RECEIVED
Controls - Main control has 4 positions:
1. OFF - All gas to the gas logs is shut off at the control
2. IGN - Piezo ignitor allows ignition of the pilot without the use of matches or batteries
3. PILOT - Valve position to light / maintain a standing pilot
4. ON - Gas flow to complete system, front burner ignition
Burner Control Knob - Infinite control, rotate clockwise to minimum rate and counterclockwise for maximum
rate. Adjust the control knob between Minimum and Maximum to gain the desired room temperature. The control
will automatically cycle the heater on and off to maintain the desired heat in the room. There are no exacts with
the adjustment, you will need to experiment with the setting to find what works best for you needs.