United States Stove VF30IN Gas Heater User Manual


 
15
The heater regulator controls the burner pressure which should be checked at the pressure test point located on the
right side of the main control and is accessible from the side of the gas log assembly (see FIGURE 6).
The pressure should be checked with the heater burning and the control set to high (HI).
The pressure regulator is preset and locked to avoid tampering. If the pressure is not as specified in Product
Specifications (Page 5), contact your dealer and replace the regulator.
FIGURE 6. Pressure Test Point Location
GAS CONNECTION
GAS PRESSURE CHECK
FIGURE 5. Option #2 for gas connection
The gas inlet connection is 3/8" NPT. Connect
gas line to gas inlet on rear of control valve
(Note: we recommend a 3/8" Flexible Gas
line. Then connect a Manual Shutoff Valve
and gas supply line as shown in FIGURES 4 &
5.
Test all gas joints from the gas meter to the
heater for leaks using soap and water solution
after completing connection. DO NOT USE
AN OPEN FLAME.