United States Stove VF30IN Gas Heater User Manual


 
16
WIRING BLOWER ASSEMBLY
To locate the blower, open the lower access door and locate the blower cover as shown in FIGURE 7. The blower
is located directly behind the blower cover. The blower comes partially pre-wired into the junction box. To
complete wiring, run the house power supply into the heater through one of the knockouts located on either side of
the firebox. Run house supply into junction box and wire as shown in wiring diagram below(Attach grounding wire
to junction box). NOTE: Junction box and bracket comes mounted to the right side (facing unit). You can also
mount the junction box on the left side if necessary.
See "Blower replace instructions" supplied with replacement blower to remove blower.
FIGURE 7. Blower Location
NOTE: If any of the original wire must
be replaced, it must be replaced with
600 volt, 150 C. wire or its equivalent.
Caution: Label all wires prior to
disconnection when servicing
controls. Wiring errors can cause
improper and dangerous operation.
Verify proper operation after
servicing.
WIRING DIAGRAM