Trane Trane Air Conditioner User Manual


 
VAV-SVN01E-EN 7
Digit 20—Attenuator
0 None
W With
Digit 21—Water Coil
0 None
1 1-Row–Plenum inlet installed RH
2 2-Row–Plenum inlet installed RH
3 1-Row–Discharge installed, LH
4 1-Row–Discharge installed, RH
5 2-Row–Discharge installed, LH
6 2-Row–Discharge installed, RH
Digit 22—Electrical Connections
L Left
R Right
Electrical Connections Note: Airflow
hitting you in the face.
Digit 23—Transformer
0 N/A (provided as standard)
Digit 24—Disconnect Switch
0 None
W With
Note: VPCF, VPWF – Toggle Disconnect
VPEF – Door Interlocking Power
Disconnect
Digit 25—Power Fuse
0 None
W With
Digit 26—Electric Heat Voltage
0 None
A 208/60/1
B 208/60/3
C 240/60/1
D 277/60/1
E 480/60/1
F 480/60/3
G 347/60/1
H 575/60/3
J 380/50/3
K 120/60/1
Digit 27, 28, 29—Electric Heat Voltage
000 None
050 0.5 kW
010 1.0 kW
015 1.5 kW
260 26.0 kW
Electric Heat Voltage Notes:
0.5 to 8.0 kW–½ kW increments
8.0 to 18.0 kW –1 kW increments
18.0 to 46.0 kW–2 kW increments
Service Model
Number Description
Fan-Powered Parallel Units
Digit 1, 2—Unit Type
VP VariTrane fan-powered parallel
Digit 3—Reheat
C Cooling Only
E Electric Heat
W Hot Water Heat
Digit 4—Development Sequence
F Sixth
Digit 5, 6—Primary Air Valve
05 5" inlet (350 max cfm)
06 6" inlet (500 max cfm)
08 8" inlet (900 max cfm)
10 10" inlet (1400 max cfm)
12 12" inlet (2000 max cfm)
14 14" inlet (3000 max cfm)
16 16" inlet (4000 max cfm)
Digit 7, 8—Secondary Air Valve
00 N/A
Digit 9—Fan
P 02SQ fan (500 nominal cfm)
Q 03SQ fan (1100 nominal cfm)
R 04SQ fan (1350 nominal cfm)
S 05SQ fan (1550 nominal cfm)
T 06SQ fan (1850 nominal cfm)
U 07SQ fan (2000 nominal cfm)
Digit 10, 11—Design Sequence
J0 Design Sequence (Factory
assigned)
Digit 12, 13, 14, 15—Controls
ENON No controls, field-installed DDC
or analog
ENCL ENON with controls enclosure
PNON No controls, field-installed
pneumatic
DD00 Trane elec actuator only
DD01 DDC – cooling only
DD02 DDC – N.C. on/off water control
DD03 DDC – prop hot water control
DD04 DDC – on/off electric heat
control
DD05 DDC – pulse-width modulation
electric heat control
DD07 DDC – N.O. on/off hot water
control
DD11 LonTalk DDC Controller—
Cooling only
DD12 LonTalk DDC Controller w/ N.C.
on/off hot water control
DD13 LonTalk DDC Controller w/
proportional hot water control
DD14 LonTalk DDC Control–on/off
electric heat control
DD15 LonTalk DDC Controller w/
pulse-width modulation electric heat
control
DD17 LonTalk DDC Controller w/ N.O.
on/off hot water control
FM00 FM customer actuator & control
FM01 FM Trane actuator w/ customer-
supplied controller
VMA2 FM Johnson Controls
VMA-1420
PWR1 FM Seimens 540-100 w/
GDE131.1P actuator
PWR4 FM Seimens 540-100 w/ Trane
actuator
PWR5 FM Seimens 540-100 w/
GDE131.1U actuator
AT01 FM Automated Logic U341V+
AT02 FM Automated Logic U141V+
EI05 Analog – fan-powered parallel
with optional on/off reheat
PN00 PN – N.O. Trane pneumatic
actuator, R.A. stat
PN05 PN – N.O. PVR, R.A. stat
Notes:
N.C. = Normally-closed
N.O = Normally-opened
DA Stat = Direct-acting pneumatic t-stat
(by others)
RA Stat = Reverse-acting pneumatic
t-stat (by others)
PN = Pneumatic
FM = Factory installation of customer-
supplied controller
PVR = Pneumatic Volume Regulator
Digit 16—Insulation
A 1/2" Matte-faced
B 1" Matte-faced
C 1/2" Foil-faced
D 1" Foil-faced
F 1" Double-wall
G 3/8" Closed-cell
Digit 17—Motor Type
D PSC Motor
E High-efficiency motor (ECM)
Digit 18—Motor Voltage
1 115/60/1
2 277/60/1
3 347/60/1
4 208/60/1
5 230/50/1
Digit 19—Outlet Connection
1 Flanged
2 Slip & Drive