Trane PKGP-PRC001-EN Heat Pump User Manual


 
PKGP-PRC001-EN
13
(15, 20 Ton)
General
Data
*Indicates both downflow and horizontal units.
Table GD-2 — General Data
15 Ton Downflow and Horizontal Units 20 Ton Downflow and Horizontal Units
WC*180B3, B4, BW WCD240B3, B4, BW WCH240B3, B4, BW
Cooling Performance
1
Gross Cooling Capacity 180,000 233,000 237,000
EER
2
9.6 9.8 10.5
Nominal CFM / ARI Rated CFM 6,000 / 5,300 8,000 / 8,000 8,000/7,000
ARI Net Cooling Capacity 168,000 222,000 224,000
Integrated Part Load Value
3
10.0 9.7 10.3
System Power KW 17.50 22.2 21.3
Heating Performance
1
High Temp. Btuh Rating 166,000 208,000 204,000
System Power KW/COP 15.69/3.10 19.65/3.10 19.29/3.10
Low Temp. Btuh Rating 88,000 118,000 118,000
System Power KW/COP 13.12/2.1 18.75/2.0 17.29/2.00
Compressor
No./Type 2/Scroll 2/Scroll 2/Scroll
Sound Rating (BELS)
4
9.2 9.4 9.4
Outdoor Coil — Type Hi-Performance Hi-Performance Hi-Performance
Tube Size (in.) OD .375 .375 .375
Face Area (sq ft) 27.12 35.3 35.3
Rows/FPI 3/16 3/16 3/16
Refrigerant Control Expansion Valve Expansion Valve Expansion Valve
Indoor Coil — Type Hi-Performance Hi-Performance Hi-Performance
Tube Size (in.) .375 .375 .375
Face Area (sq ft) 17.50 26.00 26.00
Rows/FPI 3/15 3/15 3/15
Refrigerant Control Short Orifice Capillary Tube Capillary Tube
Drain Connection No./Size (in.) 1/1.00 NPT 1/1.00 NPT 1/1.00 NPT
Outdoor Fan — Type Propeller Propeller Propeller
No. Used/Diameter (in.) 2/26 2/28 2/28
Drive Type/No. Speeds Direct/1 Direct/1 Direct/1
CFM 10,200 13,800 13,800
No. Motors/HP 2/.50 2/1.0 2/1.0
Motor RPM 1,100 1,125 1,125
Indoor Fan — Type FC Centrifugal FC Centrifugal FC Centrifugal
No. Used 1 11
Diameter x Width (in.) 15 x 15 18 x 18 18 x 18
Drive Type/No. Speeds Belt/1 Belt/1 Belt/1
No. Motors 1 1 1
Motor HP (Standard/Oversized) 3.0/5.0 5.0/7.5 5.0/7.5
Motor RPM (Standard/Oversized) 1,740/3,450 3,450/3,450 3,450/3,450
Motor Frame Size (Standard/Oversized) 145T/145T 184T/184T 184T/184T
Filters — Type Furnished
6
Throwaway Throwaway Throwaway
(No.) Size Recommended (in.) (2) 20 x 20 x 2 (4) 20 x 20 x 2 (8) 20 x 25 x 2
(4) 20 x 25 x 2 (4) 20 x 25 x 2
Refrigerant Charge (Lbs of R-22)
5
19.9/9.9 Circuit 22.0/21.0 Circuit 22.0/21.0 Circut
Notes:
1. Cooling Performance and Heating Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb. Gross capacity does not include the effect of fan motor heat.
ARI capacity is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Certified in accordance with the Unitary Large Equipment
certification program, which is based on ARI Standard 340/360-93.
2. EER is rated at ARI conditions and in accordance with ASHRAE test procedures.
3. Integrated Part Load Value is based in accordance with ARI Standard 210/240 or 340. Units are rated at 80°F entering dry bulb, and 67°F entering wet bulb at ARI rated cfm.
4. Sound Rating shown is tested in accordance with ARI Standard 270 or 370.
5. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
6. Optional 2 inch pleated filter also available.