Trane CG-PRC007-EN Air Conditioner User Manual


 
5CG-PRC007-EN
Features and
Benefits
The 10 and 15-ton air-cooled Cold
Generator
chillers, with Trane direct
drive hermetic scroll compressors, has
outstanding standard features and
additional benefits that make selection,
installation, and servicing easy.
Flexibility
Footprint
Central to the design of any project is the
operating envelope of the air-cooled
packaged chiller. With this in mind, Trane
builds the chillers to make the most
efficient use of the available installation
space. The Trane CGA model chillers are
extremely compact. They have the
lightest weight, the smallest footprint,
and the lowest silhouette of any chiller in
the industry.
Less Weight
These lightweight models afford less
stress on building supports and greater
handling ease.
Installation
Installation time and effort are reduced
when dealing with a significantly smaller
and lighter unit. In addition, having
electrical and water connections on the
same side of the unit and a single-point
main power connection serves to make
installation easier. The unit arrives at the
jobsite fully assembled, tested, charged
and ready to provide chilled water.
Ease of Service
The control panel and unit panels are
completely removable for service
accessibility and convenience.
ICS Interface
Communication with Trane Tracer
or
Tracker
is possible through the ICS
Interface on the 10 and 15 ton Cold
Generator chiller.
Optional Features
Hot Gas Bypass — Allows unit
operation below the minimum step of
unloading.
Low Ambient Head Pressure Control
— Modulates the rpm of the fan motor
in response to outdoor ambient
temperature and unit head pressure.
Provides unit cooling operation down
to outdoor temperatures of 0°F.
Coil Guard — Metal grille with PVC
coating to protect the condenser coil.
Isolation — Neoprene in shear or
spring flex isolators.
Power Supply Monitor — Provides
protection against phase loss, phase
reversal, phase imbalance, incorrect
phase sequence and low line voltage.
Elapsed Time Meter/Number Starts
Counter — Records number of
compressor starts and operating
hours.
Flow Switch — Required as a safety
interlock to prevent operation of unit
without evaporator flow (available
option for field installation only).
Integrated Comfort Systems (ICS)
Interface — Provides the ability to
communicate with Trane Tracer or
Tracker building management systems
via a Thermostat Control Module —
(TCM).
Gauges — Monitor suction and
discharge pressures.
(10–15 Ton)