Trane CA8900 Thermostat User Manual


 
4
Providing a brighter solution.™
CA8900 Z-Wave
®
Thermostat Installation Guide
Part Two: Installing Guide
Replacement installations—mount the new thermostat
in place of the old one.
New installations—follow the guidelines listed below.
Locate the thermostat on an inside wall, about 5 ft. •
(1.5m) above the floor, and in a room that is used
often.
Do not install it •
where there are
unusual heating
conditions, such
as: in direct
sunlight; near
a lamp, radio,
1 – Location of Thermostat
Good
5ft.
(1.5m)
Tools Needed
#1 Phillips screwdriver (small) •
Drill with 3/16-in. (4.8mm) bit•
television, radiator register, or fireplace; near hot
water pipes in a wall; near a stove on the other side
of a wall.
Do not locate in unusual cooling conditions, such •
as: on a wall separating an unheated room; or in a
draft from a stairwell, door, or window.
Do not locate in a damp area. This can lead to corro-•
sion that will shorten thermostat life.
Do not locate where air circulation is poor, such as: •
in a corner or an alcove; or behind an open door.
Do not install the unit until all construction work •
and painting has been completed.
This thermostat does not require leveling.•
IMPORTANT : LABEL ALL
WIRES BEFORE DISCONNECT-
ING THEM!
Switch electricity to the furnace
and air conditioner OFF; then
proceed with the following steps.
Remove cover from old thermostat. Most are snap-1.
on types and simply pull off. Some have locking
screws on the side or front. These must be loos-
ened. Note the letters printed near the terminals.
2 – Label Wires from Old Unit
B
G
W
Label the wires one at a time. You must label all the 1.
wires before you proceed.
With all wires labeled, remove them from the old 2.
unit.
3 – Remove Old Unit
Attach labels (enclosed) to each wire for identifica-2.
tion.
NOTE: Read instructions carefully before remov-
ing any wiring from existing thermostat. Wires
must be labeled before they are removed. THERE
IS NO STANDARD COLOR CODE. When remov-
ing wires from their terminals, ignore the color of
the wires since these may not comply with any
standard.
NOTE: Make sure the wires do not fall back in-
side the wall. You can wind them around a pencil
to keep them from falling.
Loosen all screws on the old thermostat and re-3.
move it from the wall.
Fill wall opening with non-combustible insulation 4.
to prevent drafts.
To avoid fire, shock, or death, and to prevent damage to the furnace, •
air conditioner, and thermostat, disconnect the power supply before
beginning work. This can be done at the circuit breaker, or at the
appliance.
Your thermostat is a precise instrument, handle it with care.•
Do not turn electricity back on until work is completed.•
WARNING–Risk of Fire or Electric Shock
Do not short (jumper) across electric terminals at control on •
furnace or air conditioner to test the system. This will damage the
thermostat and void your warranty.
All wiring must conform to local codes and ordinances.•
This thermostat is designed for use with 24 volt AC systems. The •
thermostat should be limited to a maximum of 1.0 amps; higher
amperage may cause damage to the thermostat.