Toshiba RAV-SM2242DT-TR Air Conditioner User Manual


 
– 27 –
A
B
L
N
M
(˚C)
Tc
Tcj
No.
8
9
10
Item
High-temp. release
control
Drain pump control
(
When drain up kit
sold separately is
mounted
)
After-heat
elimination
Outline of specifications
1) The heating operation is performed as follows based
on the detected temperature of Tc sensor or Tcj sensor.
When [M] zone is detected, the commanded frequency
is decreased from the real operation frequency.
After then the commanded frequency changes every
30 seconds while operation is performed in [M] zone.
In [N] zone, the commanded frequency is held.
When [L] zone is detected, the commanded fre-
quency is returned to the original value by approx.
6Hz every 60 seconds.
Setup at shipment
Control temp. (°C)
AB
56 (54) 52 (52)
1) In cooling operation, the drain pump is usually
operated.
2) If the float switch works while drain pump drives, the
compressor stops, the drain pump continues the
operation, and a check code is output.
3) If the float switch works while drain pump stops, the
compressor stops and the drain pump operates. If the
float switch keeps operating for approx. 4 minutes, a
check code is output.
When heating operation stops, in some cases, the indoor
fan operates with [FAN] for approx. 30 seconds.
Remarks
Same status as that
when “thermostat-OFF”
Check code [P10]
NOTE:
When the operation has started or when Tc or Tcj < 30°C
at start of the operation or after operation start,
temperature is controlled between values in parentheses
of A and B.
11 Use for remote start/stop
When using HA terminal
(CN61), the connecting
connector sold sepa-
rately is necessary.
In a group operation,
connect it to any of
master or follower indoor
unit for use.
HA control 1) ON/OFF is possible by HA signal input from the
remote site when it is connected to the wireless
remote unit or the remote Start/Stop I/F.
2) ON/OFF status is output to HA output terminal.
3) HA I/O specification conforms to JEMA Standard.