Toshiba RAV-SM1404UT-E Air Conditioner User Manual


 
Toshiba XXXXXXX(X/X)
–15–
4-way Air Discharge Cassette Type
Owner’s Manual
9 ADVANCED SETTINGS
How to set up swing type
1 Push for at least four seconds
when the air conditioner is not working.
, symbol, and numbers flash.
2 Select an indoor unit to be set by
pushing
(left side of the button).
Each time you push the button, unit
numbers change as follows:
The fan of the selected unit runs and the
louvers start swinging.
3 Select a swing type by pushing TIME
buttons.
CAUTION
Do not set the swing setup code to “0000”.
(This setting may cause a failure of the louvers.)
Standard swing
The four louvers swing in the same direction.
About “Dual swing”
“Dual swing” means that louvers 01 and 03 are
directed and swing in one direction,and/then
louvers 02 and 04 are directed and swing in the
opposite direction.
(When louver 01 is directed downward, louver
02 is directed horizontally.)
About “Cycle swing”
The four louvers swing independently at
respective timings.
4 Push button.
5 Push button to complete the setting.
1
2
3
Swing setup code Swing of louvers
0001
Standard swing
(Factory shipping)
0002 Dual swing
0003 Cycle swing
Not
display
Unit No.
1-1
Unit No.
1-2
Unit No.
1-3
Unit No.
1-4
Swing setup code
04 02
03
01
Refrigerant
pipe
Drain
pipe
15-EN
+00EH99930901-2_10L_4-way_OM.book Page 15 Friday, April 17, 2009 2:39 PM