Toshiba RAV-SM1101BT-E Air Conditioner User Manual


 
90
No.
Part name
Drain pump
Procedure
1. Remove the drain pan and float switch.
2. Remove the set screws (3 positions) of
fixing drain pump plate and main unit.
3. Remove the set screws (3 positions) of
fixing drain pump plate and drain pump.
Remarks
1. Remove the set screws (5 positions) and
check port cover (right side).
2. Pull out the sensor is inserted into pipe of
the heat exchanger.
1. Take down the main unit and then treat
the heat exchanger on the floor.
2. Remove the drain pan.
3. Remove the check port cover (right side).
4. Remove the set screws (6 positions) and
check port cover (left side).
5. Remove the set screws (2 positions) of
fixing heat exchanger and main unit (left
side).
6. Remove the set screws (7 positions) of
fixing heat exchanger and main unit (front
right side).
TC, TCJ sensor
Heat exchanger
Drain pump holder
Screws (Fixing drain pump holder)
Drain pump
Screws (Fixing plate and drain pump)
Drain pump holder
(6) -3. View from reverse side of drain pump
Checking port cover (Right side)
Screws (Fixing check port cover (Right side))
Check port cover (Left side)
Screws (Fixing check port cover (Left side))
Main unit (Left side)
Screws (Fixing heat exchanger)
Screws
Main unit (Front side)
6
6 -2
6 -3
7 -1
8 -4
8 -5
8 -6