Toshiba RAV-SM1101BT-E Air Conditioner User Manual


 
76
Terminal block for
remote controller cables
Remote controller
cables (Procured locally)
Indoor unit
Outdoor u
nit
Remote controller
switch (Sub)
Remote controller
switch (Master)
Sold separately
213
213
BA
Sold separately
Master remote
controller
Remote controller
address connector
Rear side of remote
controller P.C. board
Sub
remote controller
12-1-3. Cabling and Setting of Remote Controller Control
2-remote controller control (Controlled by two remote controllers)
One or multiple indoor units are controlled by two remote controllers.
(Max. 2 remote controllers are connectable.)
1 indoor unit is controlled by 2
remote controllers
(Setup method)
One or multiple indoor units are controlled by two remote controllers.
(Max. 2 remote controllers are connectable.)
<Wired remote controller>
How to set wired remote controller to sub remote
controller
Insert the remote controller address connector
provided on the rear side of the remote controller
switch P.C. board into Sub in exchange for Master.
[Operation]
1. The operation contents can be changed by Last-push-priority.
2. Use a timer on either Master remote controller or Sub remote controller.