Toshiba MMU-AP0071YH Air Conditioner User Manual


 
4
2
SELECTION OF INSTALLATION PLACE
WARNING
Install the air conditioner at enough strong place to withstand the weight of the unit.
If the strength is not enough, the unit may fall down resulting in injury.
Perform a specified installation work to guard against an earth quake.
An incomplete installation can cause accidents by the units failing and dropping.
Install the air conditioner at a height 2.5m or more from the floor.
If you insert your hands or others directly into the unit while the air conditioner operates, it is dangerous because
you may contact with revolving fan or active electricity.
CAUTION
Do not install the air conditioner in a location subject to a risk of exposure to combustible gas.
Should the combustible gas leak and collect near the unit, fire may occur.
Upon approval of the customer, install the air conditioner in a place that satisfies the following
conditions.
Place where the unit can be installed horizontally.
Place where a sufficient servicing space can be ensured for safe maintenance and check.
Place where drained water will not cause any problem.
Avoid installing in the following places.
Place exposed to air with high salt content (seaside area), or place exposed to large quantities of sulfide gas (hot
spring). (Should the unit be used in these places, special protective measures are needed.)
Place exposed to oil, vapor, oil smoke or corrosive gas.
Place where organic solvent is used nearby.
Place close to a machine generating high frequency.
Place where the discharged air blows directly into the window of the neighboring house. (For outdoor unit)
Place where noise of the outdoor unit is easily transmitted.
(When installing the air conditioner on the boundary with the neighbor, pay due attention to the level of noise.)
Place with poor ventilation.
Installation space
Reserve space required to install the indoor unit and for service work.
The lighting term setup of the filter sign (Notification of filter cleaning) of the remote controller can be changed
according to the condition of installation. If the room is not heated due to the installation place or construction of the
room, the detection temperature of heating can be raised.
For setup method, refer to Change of lighting term of filter sign and To secure better effect of heating in the
Applicable controls of this Manual.
200mm
or more
Ceiling
Ceiling inside height :
245mm or more
100mm
and more
100mm
and more
Refrigerant piping port