preferably a garden hose if possible. Return it to the filter housing
ensuring that the U-shaped gasket fits securely to the bottom of the
strainer. Make sure that the strainer head gasket is secure.
Reposition the strainer cover on top of the filter housing.
On those models with a band clamp, replace the band clamp
around the strainer cover and housing latching the T-bolt. Then
push the latch handle towards the filter housing. The T-bolt latch
does not need adjustment when installed. It is set at the factory for
proper clamp compression.
Bolted cover models require a torque sequence as follows: 12:00 to
6:00, 3:00 to 9:00, 11:00 to 5:00, and 2:00 to 7:00. Bolt torque
requirements are: 3/8” bolts (15 to 25 ft.lbs.), ½” bolts (45 to 55
ft.lbs.), and 5/8” bolts (80 to 100 ft.lbs.).
Service Notes