Soleus Air KY-32E Air Conditioner User Manual


 
OPTIONAL WATER DRAINAGE
When operating the air conditioner in cooling or dehumidifying mode under normal conditions, the condensation
water is automatically evaporated from an internal drip pan out through the exhaust duct. Under extremely high
humidity conditions, the water in the drip pan may reach a level that triggers a shut-off mechanism. The compressor
and fan will turn off and the water must be drained via one of the following two methods.
CONTINUOUS DRAINAGE
When the unit is operating on continuous drainage mode, excess condensation in the drip pan is discharged by
gravity through the drainage tube to either an external tank (not provided) or to a condensation water pump device
(Optional Item). When the unit is operating on continuous drainage mode, it can operate continuously regardless of
humidity level.
Installation Steps:
a. Remove the plug from the drainage spout.
b. Connect the drainage tubing to the drainage spout.
c. Place the other end of the drainage tube into either an
external water tank or the inlet side of a condensation
water pump.
NOTE:
Do not use lengthy drainage tubing without a condensation water pump
14