Soleus Air MA-9000AH Air Conditioner User Manual


 
is discharged by gravity through a drainage tube (12” length) to either an external hose (not
included) or to a condensate water pump device (not included). When the unit is operating on
continuous drainage mode, it can operate continuously without periodic stops to empty the water
bucket.
To allow continuous drainage:
a. Remove the water bucket from the cabinet.
b. Find the tube hanging beside the water
bucket inside of the cabinet.
c. Remove the plug from the end of the tube.
d. Connect the drainage tubing to a hose. Use a clamp
or adapter (not provided) if necessary
e. Place the other end of the hose into either an external
water bucket, a floor drain or the intake side of a
condensate water pump.
NOTE: When using the continuous drainage method, the unit will NOT shut off
automatically when an external water bucket is full. Spill water can cause substantial damages
to carpet, floors, furniture and other valuables.
NOTE: Do not use a lengthy drainage hose without a condensate water pump as water may
overflow into the internal drain bucket which requires periodic manual drainage
MAINTENANCE
Note: Before performing any maintenance activities turn the unit off and remove
the power plug from the power outlet.
15