Sierra Monitor Corporation IZS31 Air Cleaner User Manual


 
5
9. Be sure there is no incorrect wiring before operation. Incorrect wiring may cause product breakage or
malfunction.
10. Flush pneumatic piping before its installation. Make sure that all dust, water droplet, oil etc. are eliminated
before piping.
WARNING
1. Use within operating fluid and ambient temperature range.
Operating fluid and ambient temperature range for Ionizer, feed back sensor and auto balance sensor
are 0 to 50
o
C. Though ambient temperature is within specification, dew condensation might be generated
where temperature is suddenly changed. Therefore do not use under such environment.
2.Do not use this product in an enclosed space.
This product utilizes the corona discharge phenomenon. Since a small amount of ozone and NOx
is generated, do not use it in an enclosed space.
3. Environment to avoid
Do not use or store under the following environments, as these may cause operation failure. If it is
unavoidable, take the appropriate measures.
a. The place where ambient temperature exceeds 0 to 50
o
C.
b. The place where ambient humidity exceeds 35 to 85% RH.
c. The place where dew condensation is generated due to sudden temperature change.
d. The place where there is corrosive gas, inflammable gas, and volatile inflammable substance is stored.
e. The atmosphere where the product is exposed to conductive powder such as iron powder and dust, oil
mist, salt and organic solvent or machining chips, particles and cutting oil (water, liquid).
f. The place where product is directly exposed to the blow from air-conditioners.
g. The place where sealed and ventilation is not installed.
h. The place the product is exposed to the direct sunlight and radiant heat.
i. The place where strong electromagnetic noise is generated. (Strong electric field/ strong magnetic
field/ surge.)
j. The place where electricity is discharged. The situation which causes electric discharge on the product.
k. The place where strong high frequency is generated.
l. The place where lightning disaster is expected.
m. The place where the product is directly exposed to the vibration and impact.
n. The situation where the force and weight that causes deformation of the product is applied.
4. Do not use air containing mist or dust.
Air containing mist or dust may lower function and shorten maintenance cycle. Dryer (IDF series), air filter
(AF/AFF series), mist separator(AFM/AM series) to produce clean compressed air.
5. Ionizer, feed back sensor and auto balance sensor are not tolerable against surge of lightning.
Protection against lightning surge should be incorporated in the equipment..
CAUTION
1. Keep electrode needle clean by regular maintenance.
Make sure that the equipment is operating without any failure by regular
maintenance. Those who have enough knowledge and experience should
perform the maintenance of the equipment.
Dust attached on the electrode needle due to longer operating lowers the
function to eliminate static electricity. If electrode does not recover
its function to eliminate static electricity due to worn out after cleaning,
replace it with the new one. In order to maintain the stable performance,
regular maintenance and cleaning of electrode are recommended.
2. Stop supplying power to the body without fail when cleaning the electrode needle or exchanging the
electrode cartridge. Do not touch the electrode needle while energizing, or it may cause electric shock or
!
!
Environment
Maintenance
A high voltage generating circuit is
installed. Be sure to stop the supply
voltage at the maintenance. Do not
disassemble / renovate the product as
it may deteriorate the functions and
cause risks due to electric shock and
electric leakage.
Caution
for
High
Voltage