2
4
5.Specifications
5-1. Ionizer
Ionizer model IZS31(NPN) IZS31P(PNP)
Type Corona discharge
Voltage supply method Sensing DC, pulse DC, Plus DC, Minus DC
Discharge output +/- 7000 V
Ion balance *1 +/-30V (For Stainless electrode needle, from -100 to +100V)
Fluid Air (Clean dry air)
Op. pressure
(MPa)
0.7 MPa or less
Purge air
Connection
tube size
Φ4
Power supply voltage DC24 V + / - 10 %
Sensing DC mode operated 200 mA or less (When sensor is standby:120 mA or less)
Sensing DC mode stand-by 200 mA or less (When sensor is not used:170 mA or less)
Current consumption
Pulse DC mode 170mA or less
Discharge stop signal
Input signal
Maintenance start-up
signal
No-voltage contact signal
Completion signal for
static charge elimination
Maintenance output signal
Signal for failure
Maximum load current : 100mA
Residual voltage : 1V or less
(when the load current is 100mA)
Max. applied voltage:DC28V
Maximum
load current : 100 mA
Residual voltage : 1V or less
(With load current of 100 mA)
Output signal
Sensor monitor output
*2
Output voltage: 1 to 5 V (Please connect the load of 10kΩ or more.)
Effective elimination distance 50 to 2000 mm (with sensing DC mode:200 to 2000 mm)
Ambient temperature 0 to 50 ℃
Ambient humidity 35 to 80 %Rh(No dew condensation)
Material
Ionizer cover:ABS
Electrode needle:Tungsten, single crystal silicon, stainless
Vibration resistance
Endurance 50Hz Amplitude 1mm
2 hours to X,Y,Z each direction of vibration
Impact resistance 10G
Applicable standard/ directive
CE (EMC directive:89/336/EEC,92/31/EEC,93/68/EEC,2004/108/EC、
Low Voltage Directive:73/23/EEC,93/68/EEC)
※1:The distance between the charged object and ionizer is 300mm or more. With air purge.
※2:When the potential of the charged object is measured with the feed back sensor, the relation
between the charged potential and the sensor-monitor-output-voltage and the sensor detecting
range will vary depending on the installation distance between the ionizer and sensor.
[Electrode cartridge quantity and weight]
Bar length mm
300 380 620 780 1100 1260 1500 1900 2300
Q’ty of electrode
cartridge
3 4 7 9 13 15 18 23 28
Weight g
330 400 600 720 1000 1100 1500 2000 2500