Sierra Monitor Corporation IZS31 Air Cleaner User Manual


 
2
4
5.Specifications
5-1 Ionizer
Ionizer model IZS31(NPN) IZS31P(PNP)
Type Corona discharge
Voltage supply method Sensing DC, pulse DC, Plus DC, Minus DC
Discharge output +/- 7000 V
Ion balance *1 +/-30V (For Stainless electrode needle, from -100 to +100V)
Fluid Air (Clean dry air)
Op. pressure
(MPa)
0.7 MPa or less
Purge air
Connection
tube size
Φ4
Power supply voltage DC24 V + / - 10 %
Sensing DC mode operated 200 mA or less (When sensor is standby:120 mA or less)
Sensing DC mode stand-by 200 mA or less (When sensor is not used:170 mA or less)
Current consumption
Pulse DC mode 170mA or less
Discharge stop signal
Input signal
Maintenance start-up
signal
No-voltage contact signal
Completion signal for
static charge elimination
Maintenance output signal
Signal for failure
Maximum load current : 100mA
Residual voltage : 1V or less
(when the load current is 100mA)
Max. applied voltage:DC28V
Maximum
load current : 100 mA
Residual voltage : 1V or less
(With load current of 100 mA)
Output signal
Sensor monitor output
*2
Output voltage: 1 to 5 V (Please connect the load of 10kΩ or more.)
Effective elimination distance 50 to 2000 mm (with sensing DC mode:200 to 2000 mm)
Ambient temperature 0 to 50 ℃
Ambient humidity 35 to 80 %Rh(No dew condensation)
Material
Ionizer cover:ABS
Electrode needle:Tungsten, single crystal silicon, stainless
Vibration resistance
Endurance 50Hz Amplitude 1mm
2 hours to X,Y,Z each direction of vibration
Impact resistance 10G
Applicable standard/ directive
CE (EMC directive:89/336/EEC,92/31/EEC,93/68/EEC,2004/108/EC、
Low Voltage Directive:73/23/EEC,93/68/EEC)
1:The distance between the charged object and ionizer is 300mm or more. With air purge.
2:When the potential of the charged object is measured with the feed back sensor, the relation
between the charged potential and the sensor-monitor-output-voltage and the sensor detecting
range will vary depending on the installation distance between the ionizer and sensor.
Electrode cartridge quantity and weight
Bar length mm
300 380 620 780 1100 1260 1500 1900 2300
Q’ty of electrode
cartridge
3 4 7 9 13 15 18 23 28
Weight g
330 400 600 720 1000 1100 1500 2000 2500